Dosimetric and Radiobiological Comparison of Five Techniques for Postmastectomy Radiotherapy with Simultaneous Integrated Boost

المؤلفون المشاركون

Yang, Zhen
Tang, Du
Liang, Zhan
Guan, Fada

المصدر

BioMed Research International

العدد

المجلد 2020، العدد 2020 (31 ديسمبر/كانون الأول 2020)، ص ص. 1-9، 9ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2020-07-21

دولة النشر

مصر

عدد الصفحات

9

التخصصات الرئيسية

الطب البشري

الملخص EN

Purpose.

To compare five techniques for the postmastectomy radiotherapy (PMRT) with simultaneous integrated boost (SIB).

Materials and Methods.

Twenty patients with left-sided breast cancer were retrospectively selected.

Five treatment plans were created for each patient: TomoDirect (TD), unblocked helical TomoTherapy (unb-HT), blocked HT (b-HT), hybrid intensity-modulated radiotherapy (hy-IMRT), and fixed-field IMRT (ff-IMRT).

A dose of 50.4 Gy in 28 fractions to PTVtotal and 60.2 Gy in 28 fractions to PTVboost were prescribed.

The dosimetric parameters for targets and organs at risk (OARs), the normal tissue complication probability (NTCP), the second cancer complication probability (SCCP) for OARs, and the treatment efficiency were assessed and compared.

Results.

TD plans and hy-IMRT plans had similar good dose coverage and homogeneity for both PTVboost and PTVtotal and superior dose sparing for the lungs and heart.

The ff-IMRT plans had similar dosimetric results for the target volumes compared with the TD and hy-IMRT plans, but gave a relatively higher NTCP and SCCP for the lungs.

The unb-HT plans exhibited the highest OAR mean dose, highest NTCP for the lungs (0.97±1.25‰) and heart (4.58±3.62%), and highest SCCP for the lungs (3.57±0.05%) and contralateral breast (2.75±0.29%) among all techniques.

The b-HT plans significantly outperformed unb-HT plans with respect to the sparing of the lungs and heart.

This technique also showed the best conformity index (0.73±0.08) for PTVboost and the optimal NTCP for the lungs (0.03±0.03‰) and heart (0.61±0.73%).

Concerning the delivery efficiency, the hy-IMRT and ff-IMRT achieved much higher delivery efficiency compared with TomoTherapy plans.

Conclusion.

Of the five techniques studied, TD and hy-IMRT are considered the preferable options for PMRT with SIB for left-sided breast cancer treatment and can be routinely applied in clinical practice.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Tang, Du& Liang, Zhan& Guan, Fada& Yang, Zhen. 2020. Dosimetric and Radiobiological Comparison of Five Techniques for Postmastectomy Radiotherapy with Simultaneous Integrated Boost. BioMed Research International،Vol. 2020, no. 2020, pp.1-9.
https://search.emarefa.net/detail/BIM-1137963

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Tang, Du…[et al.]. Dosimetric and Radiobiological Comparison of Five Techniques for Postmastectomy Radiotherapy with Simultaneous Integrated Boost. BioMed Research International No. 2020 (2020), pp.1-9.
https://search.emarefa.net/detail/BIM-1137963

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Tang, Du& Liang, Zhan& Guan, Fada& Yang, Zhen. Dosimetric and Radiobiological Comparison of Five Techniques for Postmastectomy Radiotherapy with Simultaneous Integrated Boost. BioMed Research International. 2020. Vol. 2020, no. 2020, pp.1-9.
https://search.emarefa.net/detail/BIM-1137963

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1137963