Influence of Rotation Increments on Imaging Performance for a Rotatory Dual-Head PET System

المؤلفون المشاركون

Cao, Xu
Zhu, Shouping
Meng, Fanzhen
Cao, Xuezhou
Wang, Jianxun
Li, Liang
Liang, Jimin
Chen, Xueli

المصدر

BioMed Research International

العدد

المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-11، 11ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2017-01-05

دولة النشر

مصر

عدد الصفحات

11

التخصصات الرئيسية

الطب البشري

الملخص EN

For a rotatory dual-head positron emission tomography (PET) system, how to determine the rotation increments is an open problem.

In this study, we simulated the characteristics of a rotatory dual-head PET system.

The influences of different rotation increments were compared and analyzed.

Based on this simulation, the imaging performance of a prototype system was verified.

A reconstruction flowchart was proposed based on a precalculated system response matrix (SRM).

The SRM made the relationships between the voxels and lines of response (LORs) fixed; therefore, we added the interpolation method into the flowchart.

Five metrics, including spatial resolution, normalized mean squared error (NMSE), peak signal-to-noise ratio (PSNR), contrast-to-noise (CNR), and structure similarity (SSIM), were applied to assess the reconstructed image quality.

The results indicated that the 60° rotation increments with the bilinear interpolation had advantages in resolution, PSNR, NMSE, and SSIM.

In terms of CNR, the 90° rotation increments were better than other increments.

In addition, the reconstructed images of 90° rotation increments were also flatter than that of 60° increments.

Therefore, both the 60° and 90° rotation increments could be used in the real experiments, and which one to choose may depend on the application requirement.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Meng, Fanzhen& Cao, Xu& Cao, Xuezhou& Wang, Jianxun& Li, Liang& Chen, Xueli…[et al.]. 2017. Influence of Rotation Increments on Imaging Performance for a Rotatory Dual-Head PET System. BioMed Research International،Vol. 2017, no. 2017, pp.1-11.
https://search.emarefa.net/detail/BIM-1139189

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Meng, Fanzhen…[et al.]. Influence of Rotation Increments on Imaging Performance for a Rotatory Dual-Head PET System. BioMed Research International No. 2017 (2017), pp.1-11.
https://search.emarefa.net/detail/BIM-1139189

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Meng, Fanzhen& Cao, Xu& Cao, Xuezhou& Wang, Jianxun& Li, Liang& Chen, Xueli…[et al.]. Influence of Rotation Increments on Imaging Performance for a Rotatory Dual-Head PET System. BioMed Research International. 2017. Vol. 2017, no. 2017, pp.1-11.
https://search.emarefa.net/detail/BIM-1139189

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1139189