![](/images/graphics-bg.png)
A High Frequency Geometric Focusing Transducer Based on 1-3 Piezocomposite for Intravascular Ultrasound Imaging
المؤلفون المشاركون
Shao, Weiwei
Li, Zhangjian
Cui, Yaoyao
Han, Zhile
Xu, Jie
Jian, Xiaohua
Liu, Pengbo
Li, Peiyang
المصدر
العدد
المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2017-09-05
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
Due to the small aperture of blood vessel, a considerable disadvantage to current intravascular ultrasound (IVUS) imaging transducers is that their lateral imaging resolution is much lower than their axial resolution.
To solve this problem, a single-element, 50 MHz, 0.6 mm diameter IVUS transducer with a geometric focus at 3 mm was proposed in this paper.
The focusing transducer was based on a geometric-shaped 1-3 piezocomposite.
The impedance/phase, pulse echo, acoustic intensity field, and imaging resolution of the focusing transducer were tested.
For comparison, a flat IVUS transducer with the same diameter and 1-3 piezocomposite was made and tested too.
Compared with their results, the fabricated focusing transducer exhibits broad bandwidth (107.21%), high sensitivity (404 mV), high axial imaging resolution (80 μm), and lateral imaging resolution (100 μm).
The experimental results demonstrated that the high frequency geometric focusing piezocomposite transducer is capable of visualizing high axial and lateral resolution structure and improving the imaging quality of related interventional ultrasound imaging.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Jian, Xiaohua& Han, Zhile& Liu, Pengbo& Xu, Jie& Li, Zhangjian& Li, Peiyang…[et al.]. 2017. A High Frequency Geometric Focusing Transducer Based on 1-3 Piezocomposite for Intravascular Ultrasound Imaging. BioMed Research International،Vol. 2017, no. 2017, pp.1-8.
https://search.emarefa.net/detail/BIM-1139468
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Jian, Xiaohua…[et al.]. A High Frequency Geometric Focusing Transducer Based on 1-3 Piezocomposite for Intravascular Ultrasound Imaging. BioMed Research International No. 2017 (2017), pp.1-8.
https://search.emarefa.net/detail/BIM-1139468
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Jian, Xiaohua& Han, Zhile& Liu, Pengbo& Xu, Jie& Li, Zhangjian& Li, Peiyang…[et al.]. A High Frequency Geometric Focusing Transducer Based on 1-3 Piezocomposite for Intravascular Ultrasound Imaging. BioMed Research International. 2017. Vol. 2017, no. 2017, pp.1-8.
https://search.emarefa.net/detail/BIM-1139468
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1139468
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)