Aim.
To identify the guinea pig eyeball with edge detection and curve fitting and devise a noncontact technology of measuring ocular morphological parameters of small experimental animal.
Methods.
Thirty-nine eyeballs of guinea pig eyeballs were photographed to obtain the anterior and posterior surface; transverse and sagittal planes after the eyeballs were eviscerated.
Next, the eyeball photos were input into digital image analysis software; the corresponding photo pixels-actual length ratio was acquired by a proportional scale.
The contour lines of the eyeballs were identified by edge detection technology; conic curve fitting was applied to fit the contour line of the eyeball.
The maximum and minimum diameters, the horizontal and vertical diameters, eccentricity, tilt angle, cross-sectional area, equatorial circumference, retrobulbar equatorial maximum length, corneal radius of curvature (CRC) in central region, and the whole cornea were calculated according to the geometric principles.
The corneal data of in vitro study were compared with the in vivo results.
Results.
The contour line of the selected guinea pig eye was identified correctly by edge detection.
There were no significant differences between anterior and posterior surfaces of one eyeball in the maximum diameters, eccentricity, cross-sectional area, equatorial circumference, and tilt angle (P>0.01).
There were significant differences of eccentricity and CRC between central region and the whole cornea (P<0.01).
There were no significant differences between keratometer in vivo and cornea in vitro.
Conclusion.
It was feasible to measure an experimental animal eye in a noncontact way.
Edge detection and curve fitting technology could accurately evaluate the ocular morphological parameters.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Di, Yue& Huang, Ying& Yang, Ya-jing& Zhou, Xing-Tao& Luo, Wen-ting& Ye, Hai-yun…[et al.]. 2020. Measuring the Ocular Morphological Parameters of Guinea Pig Eye with Edge Detection and Curve Fitting. Computational and Mathematical Methods in Medicine،Vol. 2020, no. 2020, pp.1-13.
https://search.emarefa.net/detail/BIM-1139523
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Di, Yue…[et al.]. Measuring the Ocular Morphological Parameters of Guinea Pig Eye with Edge Detection and Curve Fitting. Computational and Mathematical Methods in Medicine No. 2020 (2020), pp.1-13.
https://search.emarefa.net/detail/BIM-1139523
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Di, Yue& Huang, Ying& Yang, Ya-jing& Zhou, Xing-Tao& Luo, Wen-ting& Ye, Hai-yun…[et al.]. Measuring the Ocular Morphological Parameters of Guinea Pig Eye with Edge Detection and Curve Fitting. Computational and Mathematical Methods in Medicine. 2020. Vol. 2020, no. 2020, pp.1-13.
https://search.emarefa.net/detail/BIM-1139523
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1139523
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر