Delayed Development of Coronary Ostial Stenosis following Surgical Aortic Valve Replacement: A Case Report of Unusual Presentation
المؤلفون المشاركون
Shin, Doosup
Huang, Kevin
Sunjic, Igor
Berlowitz, Michael
Prida, Xavier
المصدر
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-4، 4ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-04-01
دولة النشر
مصر
عدد الصفحات
4
التخصصات الرئيسية
الملخص EN
Coronary ostial stenosis is a rare but potentially life-threatening complication that occurs in 1%–5% of patients who undergo surgical aortic valve replacement (SAVR).
Symptoms typically appear within the first 6 months and almost always within a year after SAVR.
We report an unusually delayed presentation of non-ST segment elevation myocardial infarction due to coronary ostial stenosis 22 months after SAVR.
A 71-year-old woman underwent uncomplicated SAVR with a bioprosthetic valve in August 2015 for severe aortic stenosis.
A preoperative coronary angiogram demonstrated widely patent left and right coronary arteries.
In June 2017, the patient presented to the hospital with chest pain.
An electrocardiogram demonstrated 1 mm ST segment depression in the anterolateral leads, and serum troponin I level was elevated to 2.3 ng/ml.
Diagnostic coronary angiography revealed severe ostial stenosis (99%) of the right coronary artery.
A bare-metal stent was successfully placed with an excellent angiographic result, and the patient was asymptomatic at 4 months of follow-up after the procedure.
As seen in our case, coronary ostial stenosis should be considered in the differential diagnosis of chest pain or arrhythmia in patients presenting with a history of SAVR, even if the procedure was performed more than 1 year prior to presentation.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Shin, Doosup& Huang, Kevin& Sunjic, Igor& Berlowitz, Michael& Prida, Xavier. 2018. Delayed Development of Coronary Ostial Stenosis following Surgical Aortic Valve Replacement: A Case Report of Unusual Presentation. Case Reports in Cardiology،Vol. 2018, no. 2018, pp.1-4.
https://search.emarefa.net/detail/BIM-1141335
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Shin, Doosup…[et al.]. Delayed Development of Coronary Ostial Stenosis following Surgical Aortic Valve Replacement: A Case Report of Unusual Presentation. Case Reports in Cardiology No. 2018 (2018), pp.1-4.
https://search.emarefa.net/detail/BIM-1141335
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Shin, Doosup& Huang, Kevin& Sunjic, Igor& Berlowitz, Michael& Prida, Xavier. Delayed Development of Coronary Ostial Stenosis following Surgical Aortic Valve Replacement: A Case Report of Unusual Presentation. Case Reports in Cardiology. 2018. Vol. 2018, no. 2018, pp.1-4.
https://search.emarefa.net/detail/BIM-1141335
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1141335
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر