Diabetes Mellitus with Poor Glycemic Control as a Consequence of Inappropriate Injection Technique
المؤلفون المشاركون
Poudel, Ramesh Sharma
Shrestha, Shakti
Bhandari, Sushma
Piryani, Rano Mal
Adhikari, Shital
المصدر
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-4، 4ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-04-01
دولة النشر
مصر
عدد الصفحات
4
التخصصات الرئيسية
الملخص EN
Majority of patients with diabetes mellitus (DM), who are on insulin therapy, use insulin pen for convenience, accuracy, and comfort.
Some patients may require two different types of insulin preparations for better glycemic control.
We have reported a case of poor glycemic control as a consequence of inappropriate insulin injection technique.
A 57-year-old man with type 2 DM had been using premix insulin 30 : 70 for his glycemic control for the last 12 years.
On follow-up visit, his blood sugar level (BSL) had increased; therefore the treating physician increased the dose of premix insulin and added basal insulin with the aim of controlling his blood sugar level.
Despite these changes, his BSL was significantly higher than his previous level.
On investigation, the cause of his poor glycemic control was found to be due to inadequate delivery of insulin (primarily premix) as a consequence of lack of priming and incompatibility of single insulin pen for two cartridges.
His basal insulin was discontinued and the patient along with his grandson was instructed to administer insulin correctly.
After correction of the errors, the patient had a better glycemic control.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Poudel, Ramesh Sharma& Shrestha, Shakti& Bhandari, Sushma& Piryani, Rano Mal& Adhikari, Shital. 2018. Diabetes Mellitus with Poor Glycemic Control as a Consequence of Inappropriate Injection Technique. Case Reports in Endocrinology،Vol. 2018, no. 2018, pp.1-4.
https://search.emarefa.net/detail/BIM-1143018
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Poudel, Ramesh Sharma…[et al.]. Diabetes Mellitus with Poor Glycemic Control as a Consequence of Inappropriate Injection Technique. Case Reports in Endocrinology No. 2018 (2018), pp.1-4.
https://search.emarefa.net/detail/BIM-1143018
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Poudel, Ramesh Sharma& Shrestha, Shakti& Bhandari, Sushma& Piryani, Rano Mal& Adhikari, Shital. Diabetes Mellitus with Poor Glycemic Control as a Consequence of Inappropriate Injection Technique. Case Reports in Endocrinology. 2018. Vol. 2018, no. 2018, pp.1-4.
https://search.emarefa.net/detail/BIM-1143018
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1143018
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر