False Positive Transit Time Flowmetry Graft Failure in Multivessel Coronary Spasm following Off-Pump Coronary Artery Bypass Grafting

المؤلفون المشاركون

Krasopoulos, George
Kassimis, George

المصدر

Case Reports in Cardiology

العدد

المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-3، 3ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2017-05-28

دولة النشر

مصر

عدد الصفحات

3

التخصصات الرئيسية

الأمراض

الملخص EN

Intraoperative Transit Time Flowmetry is currently recommended to assess graft patency during coronary artery bypass grafting (CABG), especially in presence of haemodynamic instability or inability to wean the patient from cardiopulmonary bypass, new regional wall motion abnormalities, or significant ventricular arrhythmias.

The VeriQ™ system is one of the currently available systems, which detects imperfections that may be corrected by graft revision.

In this case report, multivessel coronary spasm (CS) post-CABG interferes with these intraoperative parameters misleading initially into false results.

Cardiac surgeons should bear in mind the limit of VeriQ in distinguishing between graft failure and CS.

Angiography may be considered in patients with decreased graft flow despite revision of anastomosis and vasodilatory treatment for the definitive diagnosis.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Kassimis, George& Krasopoulos, George. 2017. False Positive Transit Time Flowmetry Graft Failure in Multivessel Coronary Spasm following Off-Pump Coronary Artery Bypass Grafting. Case Reports in Cardiology،Vol. 2017, no. 2017, pp.1-3.
https://search.emarefa.net/detail/BIM-1143996

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Kassimis, George& Krasopoulos, George. False Positive Transit Time Flowmetry Graft Failure in Multivessel Coronary Spasm following Off-Pump Coronary Artery Bypass Grafting. Case Reports in Cardiology No. 2017 (2017), pp.1-3.
https://search.emarefa.net/detail/BIM-1143996

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Kassimis, George& Krasopoulos, George. False Positive Transit Time Flowmetry Graft Failure in Multivessel Coronary Spasm following Off-Pump Coronary Artery Bypass Grafting. Case Reports in Cardiology. 2017. Vol. 2017, no. 2017, pp.1-3.
https://search.emarefa.net/detail/BIM-1143996

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1143996