![](/images/graphics-bg.png)
Optic Nerve Sheath Diameter as a Bedside Assessment for Elevated Intracranial Pressure
المؤلف
المصدر
العدد
المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-2، 2ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2017-04-05
دولة النشر
مصر
عدد الصفحات
2
التخصصات الرئيسية
الملخص EN
A previously fit and healthy 26-year-old lady with no significant medical history presented with a two-month history of headaches.
The headaches were prolonged, generalised, and unusually severe for the patient.
Examination revealed papilloedema.
The patient’s optic nerve sheath diameter was measured 3 mm posterior to the globe and found to be 7.5 mm.
The patient subsequently had computed tomography scan of her brain that showed an optic nerve sheath diameter of 7.56 mm as measured 3 mm posterior to the globe.
After an obstructive lesion was ruled out on the computed tomography scan, a lumbar puncture was then performed and cerebrospinal fluid was drained.
An ultrasound of the optic nerve sheath diameter was repeated showing a reduced diameter of 5.6 mm.
The patient was admitted to the neurology unit and ultimately diagnosed with idiopathic intracranial hypertension.
This case report highlights the potential of rapidly identifying elevated intracranial pressure using a noninvasive method.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Williams, Peter. 2017. Optic Nerve Sheath Diameter as a Bedside Assessment for Elevated Intracranial Pressure. Case Reports in Critical Care،Vol. 2017, no. 2017, pp.1-2.
https://search.emarefa.net/detail/BIM-1144362
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Williams, Peter. Optic Nerve Sheath Diameter as a Bedside Assessment for Elevated Intracranial Pressure. Case Reports in Critical Care No. 2017 (2017), pp.1-2.
https://search.emarefa.net/detail/BIM-1144362
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Williams, Peter. Optic Nerve Sheath Diameter as a Bedside Assessment for Elevated Intracranial Pressure. Case Reports in Critical Care. 2017. Vol. 2017, no. 2017, pp.1-2.
https://search.emarefa.net/detail/BIM-1144362
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1144362
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)