Modified Descemet’s Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries
المؤلفون المشاركون
Oyakawa, Itaru
Kato, Naoko
Hayashi, Takahiko
Shimizu, Toshiki
المصدر
Case Reports in Ophthalmological Medicine
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-5، 5ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-02-01
دولة النشر
مصر
عدد الصفحات
5
التخصصات الرئيسية
الملخص EN
Purpose.
Descemet’s stripping automated endothelial keratoplasty (DSAEK) is more difficult in hypotonic eyes with filtering bleb, due to the difficulties in elevating the intraocular pressure (IOP).
We report a new method that uses ophthalmic viscoelastic devices (OVDs) to achieve good graft adhesion.
Case Presentation.
We performed modified DSAEK surgery on 2 eyes of 2 patients, who had previously undergone a trabeculectomy.
Both eyes had functioning filtering blebs; the IOP was lower than 10 mmHg without medication.
After the graft was inserted into the anterior chamber, the conjunctiva was penetrated, apart from the bleb, using a 30 G needle, and Healon V® was injected into the bleb until the encapsulated space was filled completely.
Air was subsequently injected into the anterior chamber to promote the graft attachment to the back surface of the cornea.
The IOP was elevated above 40 mmHg in both eyes 1 h after surgery and then decreased to less than 30 mmHg over the subsequent 3 h period.
The implanted graft showed good adhesion and no dislocation.
Conclusions.
Our novel DSAEK procedure that adds one step of OVD injection into the filtering bleb may be useful for hypotonic eyes that had undergone filtering surgeries.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Oyakawa, Itaru& Hayashi, Takahiko& Shimizu, Toshiki& Kato, Naoko. 2018. Modified Descemet’s Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries. Case Reports in Ophthalmological Medicine،Vol. 2018, no. 2018, pp.1-5.
https://search.emarefa.net/detail/BIM-1146830
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Oyakawa, Itaru…[et al.]. Modified Descemet’s Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries. Case Reports in Ophthalmological Medicine No. 2018 (2018), pp.1-5.
https://search.emarefa.net/detail/BIM-1146830
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Oyakawa, Itaru& Hayashi, Takahiko& Shimizu, Toshiki& Kato, Naoko. Modified Descemet’s Stripping Automated Endothelial Keratoplasty: The Use of Ophthalmic Viscoelastic Devices in Hypotonic Eyes That Had Undergone Glaucoma Filtering Surgeries. Case Reports in Ophthalmological Medicine. 2018. Vol. 2018, no. 2018, pp.1-5.
https://search.emarefa.net/detail/BIM-1146830
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1146830
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر