الملخص EN
Hydrothorax is a well-known but rare complication of peritoneal dialysis (PD), with an average incidence of 2% mainly in cases of continuous ambulatory peritoneal dialysis (CAPD).
In more than 80% of these cases, the hydrothorax is attributed to an abnormal pleuroperitoneal communication.
It commonly manifests as unilateral effusion, predominantly on the right.
A thoracentesis to determine pleural glucose has been a diagnostic aid well relied on, as the dextrose rich dialysate raises the pleural fluid glucose.
A pleural fluid glucose to serum glucose gradient greater than 50 mg/dL is suggestive of a leak with a specificity of 100% according to some studies; however, its sensitivity is variable.
Our case illustrates a diagnostic dilemma due to a relatively low pleural fluid to serum glucose gradient of 21 mg/dL that caused a delay in diagnosis.
A pleural fluid to serum glucose ratio >1.0 was used as a diagnostic marker that pointed toward a peritoneal leak.
For confirmation, a peritoneal scintigraphy with nuclear technetium 99 scan was performed that revealed a pleuroperitoneal fistula as the source of the recurring hydrothorax in the setting of automated peritoneal dialysis (APD).
The hydrothorax completely resolved with termination of APD on follow-up as the patient was transitioned to intermittent hemodialysis (HD).
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Bohra, Nidrit& Sullivan, Abigayle& Chaudhary, Haseeb& Demko, Trudy. 2020. The Use of Pleural Fluid to Serum Glucose Ratio in Establishing the Diagnosis of a Not So Sweet PD-Related Hydrothorax: Case Report and Literature Review. Case Reports in Nephrology،Vol. 2020, no. 2020, pp.1-4.
https://search.emarefa.net/detail/BIM-1148804
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Sullivan, Abigayle…[et al.]. The Use of Pleural Fluid to Serum Glucose Ratio in Establishing the Diagnosis of a Not So Sweet PD-Related Hydrothorax: Case Report and Literature Review. Case Reports in Nephrology No. 2020 (2020), pp.1-4.
https://search.emarefa.net/detail/BIM-1148804
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Bohra, Nidrit& Sullivan, Abigayle& Chaudhary, Haseeb& Demko, Trudy. The Use of Pleural Fluid to Serum Glucose Ratio in Establishing the Diagnosis of a Not So Sweet PD-Related Hydrothorax: Case Report and Literature Review. Case Reports in Nephrology. 2020. Vol. 2020, no. 2020, pp.1-4.
https://search.emarefa.net/detail/BIM-1148804
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1148804
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر