Extensor Tendon Dislocation at the Metacarpophalangeal Joint of Both Ring Fingers Caused by a Specific Hand Posture in a Shiatsu Therapist

المؤلفون المشاركون

Sasaki, Gen
Kamiya, Mariko
Ikuta, Kensuke
Miyamoto, Hideaki
Kimura, Michio
Kawano, Hirotaka

المصدر

Case Reports in Orthopedics

العدد

المجلد 2020، العدد 2020 (31 ديسمبر/كانون الأول 2020)، ص ص. 1-4، 4ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2020-09-23

دولة النشر

مصر

عدد الصفحات

4

التخصصات الرئيسية

الطب البشري

الملخص EN

A 43-year-old female shiatsu therapist complained of sudden snapping of the metacarpophalangeal joints (MCPjs) of both ring fingers during a specific hand posture.

The extensor tendon of the ring finger was dislocated ulnarly when the MCPj of the ring finger was flexed and deviated ulnarly and the MCPj of the middle finger was extended.

Surgical exploration revealed an attenuated radial sagittal band.

We plicated the juncturae tendinum of the extensor digitorum communis between the middle and ring fingers and released the ulnar sagittal band partially to centralise the extensor tendon excursion.

Twenty-six months postoperatively, the patient regained full active and passive range of motion of all fingers without extensor tendon dislocation or snapping in either hand during work.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Kamiya, Mariko& Sasaki, Gen& Ikuta, Kensuke& Miyamoto, Hideaki& Kimura, Michio& Kawano, Hirotaka. 2020. Extensor Tendon Dislocation at the Metacarpophalangeal Joint of Both Ring Fingers Caused by a Specific Hand Posture in a Shiatsu Therapist. Case Reports in Orthopedics،Vol. 2020, no. 2020, pp.1-4.
https://search.emarefa.net/detail/BIM-1149971

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Kamiya, Mariko…[et al.]. Extensor Tendon Dislocation at the Metacarpophalangeal Joint of Both Ring Fingers Caused by a Specific Hand Posture in a Shiatsu Therapist. Case Reports in Orthopedics No. 2020 (2020), pp.1-4.
https://search.emarefa.net/detail/BIM-1149971

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Kamiya, Mariko& Sasaki, Gen& Ikuta, Kensuke& Miyamoto, Hideaki& Kimura, Michio& Kawano, Hirotaka. Extensor Tendon Dislocation at the Metacarpophalangeal Joint of Both Ring Fingers Caused by a Specific Hand Posture in a Shiatsu Therapist. Case Reports in Orthopedics. 2020. Vol. 2020, no. 2020, pp.1-4.
https://search.emarefa.net/detail/BIM-1149971

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1149971