Repair of Proximal Hamstring Tear Utilizing a Suture Bridge Knotless Construct

المؤلفون المشاركون

Sanderson, Brent
Stumetz, Kyle
Jazayeri, Reza

المصدر

Case Reports in Orthopedics

العدد

المجلد 2020، العدد 2020 (31 ديسمبر/كانون الأول 2020)، ص ص. 1-5، 5ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2020-08-03

دولة النشر

مصر

عدد الصفحات

5

التخصصات الرئيسية

الطب البشري

الملخص EN

Proximal hamstring tendon injuries occur frequently in the athletic population resulting in varying degrees of functional disability depending on severity of injury.

The purpose of our case vignette is to describe a surgical technique and clinical outcome for open proximal hamstring tendon repair with a confirmed biomechanically sound construct.

We also describe and summarize the current literature recommendations for proximal hamstring injuries.

We present a case and surgical technique report on a 27-year-old male who suffered a proximal hamstring tendon rupture.

Utilizing a double row all-knotless suture bridge construct with a total of four anchors and six suture limbs allowed for anatomic footprint coverage and strength.

Two years of clinical follow-up was obtained evaluating hip and knee range of motion, strength, and functional ability.

Our patient underwent uncomplicated open surgical repair and returned to all activity at four months following surgery.

Range of motion and strength returned to preoperative levels at the four-month postoperative mark.

The use of a reproducible double row all-knotless suture bridge technique provided adequate strength and stability in the setting of a proximal hamstring tendon rupture.

Open and endoscopic surgical techniques performed acutely both show positive postoperative subjective outcomes as well as a high likelihood of returning to sport.

Controversy remains present in regard to the repair technique as well as postoperative bracing and physical therapy recommendations.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Sanderson, Brent& Stumetz, Kyle& Jazayeri, Reza. 2020. Repair of Proximal Hamstring Tear Utilizing a Suture Bridge Knotless Construct. Case Reports in Orthopedics،Vol. 2020, no. 2020, pp.1-5.
https://search.emarefa.net/detail/BIM-1150075

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Sanderson, Brent…[et al.]. Repair of Proximal Hamstring Tear Utilizing a Suture Bridge Knotless Construct. Case Reports in Orthopedics No. 2020 (2020), pp.1-5.
https://search.emarefa.net/detail/BIM-1150075

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Sanderson, Brent& Stumetz, Kyle& Jazayeri, Reza. Repair of Proximal Hamstring Tear Utilizing a Suture Bridge Knotless Construct. Case Reports in Orthopedics. 2020. Vol. 2020, no. 2020, pp.1-5.
https://search.emarefa.net/detail/BIM-1150075

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1150075