Insufficient Humidification of Respiratory Gases in Patients Who Are Undergoing Therapeutic Hypothermia at a Paediatric and Adult Intensive Care Unit

المؤلفون المشاركون

Tanaka, Yukari
Iwata, Sachiko
Kinoshita, Masahiro
Tsuda, Kennosuke
Tanaka, Shoichiro
Hara, Naoko
Shindou, Ryota
Harada, Eimei
Kijima, Ryouji
Yamaga, Osamu
Ohkuma, Hitoe
Ushijima, Kazuo
Sakamoto, Teruo
Yamashita, Yushiro
Iwata, Osuke

المصدر

Canadian Respiratory Journal

العدد

المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-6، 6ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2017-04-20

دولة النشر

مصر

عدد الصفحات

6

التخصصات الرئيسية

الأمراض
الطب البشري

الملخص EN

For cooled newborn infants, humidifier settings for normothermic condition provide excessive gas humidity because absolute humidity at saturation is temperature-dependent.

To assess humidification of respiratory gases in patients who underwent moderate therapeutic hypothermia at a paediatric/adult intensive care unit, 6 patients were studied over 9 times.

Three humidifier settings, 37-default (chamber-outlet, 37°C; Y-piece, 40°C), 33.5-theoretical (chamber-outlet, 33.5°C; Y-piece, 36.5°C), and 33.5-adjusted (optimised setting to achieve saturated vapour at 33.5°C using feedback from a thermohygrometer), were tested.

Y-piece gas temperature/humidity and the incidence of high (>40.6 mg/L) and low (<32.9 mg/L) humidity relative to the target level (36.6 mg/L) were assessed.

Y-piece gas humidity was 32.0 (26.8–37.3), 22.7 (16.9–28.6), and 36.9 (35.5–38.3) mg/L {mean (95% confidence interval)} for 37-default setting, 33.5-theoretical setting, and 33.5-adjusted setting, respectively.

High humidity was observed in 1 patient with 37-default setting, whereas low humidity was seen in 5 patients with 37-default setting and 8 patients with 33.5-theoretical setting.

With 33.5-adjusted setting, inadequate Y-piece humidity was not observed.

Potential risks of the default humidifier setting for insufficient respiratory gas humidification were highlighted in patients cooled at a paediatric/adult intensive care unit.

Y-piece gas conditions can be controlled to the theoretically optimal level by adjusting the setting guided by Y-piece gas temperature/humidity.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Tanaka, Yukari& Iwata, Sachiko& Kinoshita, Masahiro& Tsuda, Kennosuke& Tanaka, Shoichiro& Hara, Naoko…[et al.]. 2017. Insufficient Humidification of Respiratory Gases in Patients Who Are Undergoing Therapeutic Hypothermia at a Paediatric and Adult Intensive Care Unit. Canadian Respiratory Journal،Vol. 2017, no. 2017, pp.1-6.
https://search.emarefa.net/detail/BIM-1150886

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Tanaka, Yukari…[et al.]. Insufficient Humidification of Respiratory Gases in Patients Who Are Undergoing Therapeutic Hypothermia at a Paediatric and Adult Intensive Care Unit. Canadian Respiratory Journal No. 2017 (2017), pp.1-6.
https://search.emarefa.net/detail/BIM-1150886

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Tanaka, Yukari& Iwata, Sachiko& Kinoshita, Masahiro& Tsuda, Kennosuke& Tanaka, Shoichiro& Hara, Naoko…[et al.]. Insufficient Humidification of Respiratory Gases in Patients Who Are Undergoing Therapeutic Hypothermia at a Paediatric and Adult Intensive Care Unit. Canadian Respiratory Journal. 2017. Vol. 2017, no. 2017, pp.1-6.
https://search.emarefa.net/detail/BIM-1150886

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1150886