Use of the Minimally Invasive Reduction Instrumentation System for Facilitating Alignment and Reduction When Performing Minimally Invasive Plate Osteosynthesis in Three Dogs
المؤلفون المشاركون
Lewis, Daniel D.
Townsend, Sarah
المصدر
Case Reports in Veterinary Medicine
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-04-15
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
The Minimally Invasive Reduction Instrumentation System (MIRIS) was utilized to facilitate minimally invasive plate osteosynthesis (MIPO) of distal limb diaphyseal comminuted fractures (2 crural, 1 antebrachial) in three dogs.
The MIRIS facilitated efficient MIPO in all three fractures.
Radial and tibial lengths were restored within 2% of the length of the intact bone and postoperative frontal and sagittal plane angulation were within 3° of the normal contralateral limb for each of the fractures.
Fixation failed in one of the tibial fractures when the plates bent a week following surgery.
The implants were removed and the fracture was restabilized via MIPO facilitated by the MIRIS.
Inappropriate implant selection was considered the primary reason for implant failure.
All three fractures achieved union by 10 weeks following surgery.
The dog that underwent revision surgery developed a surgical site infection 5 months following revision surgery, which necessitated implant removal.
All three dogs had excellent limb function at the time of the final evaluation.
This system resulted in reductions that were near anatomic, with acceptable restoration of length and alignment and excellent limb function.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Townsend, Sarah& Lewis, Daniel D.. 2018. Use of the Minimally Invasive Reduction Instrumentation System for Facilitating Alignment and Reduction When Performing Minimally Invasive Plate Osteosynthesis in Three Dogs. Case Reports in Veterinary Medicine،Vol. 2018, no. 2018, pp.1-8.
https://search.emarefa.net/detail/BIM-1151660
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Townsend, Sarah& Lewis, Daniel D.. Use of the Minimally Invasive Reduction Instrumentation System for Facilitating Alignment and Reduction When Performing Minimally Invasive Plate Osteosynthesis in Three Dogs. Case Reports in Veterinary Medicine No. 2018 (2018), pp.1-8.
https://search.emarefa.net/detail/BIM-1151660
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Townsend, Sarah& Lewis, Daniel D.. Use of the Minimally Invasive Reduction Instrumentation System for Facilitating Alignment and Reduction When Performing Minimally Invasive Plate Osteosynthesis in Three Dogs. Case Reports in Veterinary Medicine. 2018. Vol. 2018, no. 2018, pp.1-8.
https://search.emarefa.net/detail/BIM-1151660
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1151660
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر