The Effect of a Mechanical Compression Device and Supraglottic Airway on Flow Time: A Simulation Study of Out-of-Hospital Cardiac Arrest in a High-Rise Building

المؤلفون المشاركون

Maria, Sonja J.
Kim, Jongho
Brewster, Lyle
Moon, Jundong

المصدر

Emergency Medicine International

العدد

المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-6، 6ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2018-07-16

دولة النشر

مصر

عدد الصفحات

6

التخصصات الرئيسية

الطب البشري

الملخص EN

High-rise buildings present unique challenges to providing high-quality CPR.

We investigated the effect of using a mechanical compressor and supraglottic airway on flow time and CPR quality in simulated cardiac arrests occurring within a high-rise building.

Twelve teams of EMS providers performed CPR according to 4 scenarios: manual compression and ventilation through bag-valve-mask (MAB) or supraglottic airway (MAS); mechanical compression and ventilation through bag-valve-mask (MEB) or supraglottic airway (MES).

Chest compression indices did not differ significantly among the groups.

The mechanical compression groups had a higher flow time fraction from exiting the elevator until the manikin was loaded into the ambulance than the manual compression groups.

The supraglottic airway groups had higher flow time fractions from entering the elevator until the end of the scenario than the bag-valve-mask groups.

The total flow time fraction was lowest in the MAB group and was highest in the MEB group (P < 0.001).

In simulated cardiac arrest in a high-rise building, the use of a supraglottic airway maintained flow time at a level similar to that observed with the use of a mechanical compressor.

Moreover, the use of a mechanical compressor and a supraglottic airway increased the flow time most effectively.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Kim, Jongho& Brewster, Lyle& Maria, Sonja J.& Moon, Jundong. 2018. The Effect of a Mechanical Compression Device and Supraglottic Airway on Flow Time: A Simulation Study of Out-of-Hospital Cardiac Arrest in a High-Rise Building. Emergency Medicine International،Vol. 2018, no. 2018, pp.1-6.
https://search.emarefa.net/detail/BIM-1157087

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Kim, Jongho…[et al.]. The Effect of a Mechanical Compression Device and Supraglottic Airway on Flow Time: A Simulation Study of Out-of-Hospital Cardiac Arrest in a High-Rise Building. Emergency Medicine International No. 2018 (2018), pp.1-6.
https://search.emarefa.net/detail/BIM-1157087

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Kim, Jongho& Brewster, Lyle& Maria, Sonja J.& Moon, Jundong. The Effect of a Mechanical Compression Device and Supraglottic Airway on Flow Time: A Simulation Study of Out-of-Hospital Cardiac Arrest in a High-Rise Building. Emergency Medicine International. 2018. Vol. 2018, no. 2018, pp.1-6.
https://search.emarefa.net/detail/BIM-1157087

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1157087