Utility of a Modified Oropharyngeal Airway for Performing Tracheal Intubation Using a Fiberoptic Bronchoscope and Video Stylet: A Randomized Crossover Trial Using a Manikin

المؤلفون المشاركون

Lee, Jang Hee
Na, Ji Ung
Shin, Dong Hyuk
Choi, Pil Cho
Park, Sang O
Han, Sang Kuk
Kim, Won Jae

المصدر

Emergency Medicine International

العدد

المجلد 2020، العدد 2020 (31 ديسمبر/كانون الأول 2020)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2020-10-29

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

الطب البشري

الملخص EN

Purpose.

The purpose of this study was to assess if a modified airway (MA), developed by the authors, would act as a guide and improve the performance of intubation when used with a video stylet (VS) or fiberoptic bronchoscope (FOB) for endotracheal intubation.

Methods.

This randomized crossover simulation study using manikins was conducted with 36 novice operators.

Time to complete intubation, time to see the glottis, and success rate of intubation of each device were measured and compared with or without use of MA.

Results.

For intubation using FOB with MA, the median time to complete intubation significantly reduced from 46 to 31 seconds with a medium effect size (p=0.004, r = 0.483), and the median time to see the glottis significantly reduced from 7 to 5 seconds with a medium effect size (p=0.032, r = 0.357).

The overall success rate was not statistically different between FOB with MA (33/36, 91.7%) and FOB alone (31/36, 86.1%); however, the cumulative success rate over time for FOB with MA was higher than that for FOB alone (p=0.333).

For intubation using VS, there were no differences in the time to see the glottis and time to complete intubation between VS with MA and VS alone (p=0.065 and p=0.926, respectively), and the cumulative success rate was not statistically significant (p=0.594).

Conclusion.

Adjunct use of MA helped reduce time to complete intubation in FOB, but not in VS.

If an inexperienced operator uses FOB, it would be helpful to use MA as an adjunct device.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Lee, Jang Hee& Na, Ji Ung& Shin, Dong Hyuk& Choi, Pil Cho& Park, Sang O& Kim, Won Jae…[et al.]. 2020. Utility of a Modified Oropharyngeal Airway for Performing Tracheal Intubation Using a Fiberoptic Bronchoscope and Video Stylet: A Randomized Crossover Trial Using a Manikin. Emergency Medicine International،Vol. 2020, no. 2020, pp.1-7.
https://search.emarefa.net/detail/BIM-1159011

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Lee, Jang Hee…[et al.]. Utility of a Modified Oropharyngeal Airway for Performing Tracheal Intubation Using a Fiberoptic Bronchoscope and Video Stylet: A Randomized Crossover Trial Using a Manikin. Emergency Medicine International No. 2020 (2020), pp.1-7.
https://search.emarefa.net/detail/BIM-1159011

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Lee, Jang Hee& Na, Ji Ung& Shin, Dong Hyuk& Choi, Pil Cho& Park, Sang O& Kim, Won Jae…[et al.]. Utility of a Modified Oropharyngeal Airway for Performing Tracheal Intubation Using a Fiberoptic Bronchoscope and Video Stylet: A Randomized Crossover Trial Using a Manikin. Emergency Medicine International. 2020. Vol. 2020, no. 2020, pp.1-7.
https://search.emarefa.net/detail/BIM-1159011

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1159011