Failure Diagnosis for Demagnetization in Interior Permanent Magnet Synchronous Motors
المؤلفون المشاركون
Ishikawa, Takeo
Igarashi, Naoto
Kurita, Nobuyuki
المصدر
International Journal of Rotating Machinery
العدد
المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-13، 13ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2017-10-16
دولة النشر
مصر
عدد الصفحات
13
التخصصات الرئيسية
الملخص EN
Since a high degree of reliability is necessary for permanent magnet synchronous motors, the detection of a precursor for the demagnetization of permanent magnets is very important.
This paper investigates the diagnosis of very slight PM demagnetization.
The permanent magnet volume is altered so as to mimic the effect of demagnetization.
This paper investigates the influence of demagnetization by using several methods: the 3D finite element analysis (FEA) of the motor, the measurement of high-frequency impedance, and the measurement and FEA of the stator voltage and current under vector control.
We have obtained the following results.
The back-EMF is proportional to permanent magnet volume, and there is no difference in the demagnetization in the radial direction and in the axial direction.
Even harmonics and subharmonics of flux density at the teeth tip could be useful for diagnosis if a search coil is installed there.
The relatively low frequency resistance at the d-axis position is useful for diagnosis.
Under vector control, the stator voltage is useful except in an intermediate torque range, and the intermediate torque is expressed by a simple equation.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Ishikawa, Takeo& Igarashi, Naoto& Kurita, Nobuyuki. 2017. Failure Diagnosis for Demagnetization in Interior Permanent Magnet Synchronous Motors. International Journal of Rotating Machinery،Vol. 2017, no. 2017, pp.1-13.
https://search.emarefa.net/detail/BIM-1169496
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Ishikawa, Takeo…[et al.]. Failure Diagnosis for Demagnetization in Interior Permanent Magnet Synchronous Motors. International Journal of Rotating Machinery No. 2017 (2017), pp.1-13.
https://search.emarefa.net/detail/BIM-1169496
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Ishikawa, Takeo& Igarashi, Naoto& Kurita, Nobuyuki. Failure Diagnosis for Demagnetization in Interior Permanent Magnet Synchronous Motors. International Journal of Rotating Machinery. 2017. Vol. 2017, no. 2017, pp.1-13.
https://search.emarefa.net/detail/BIM-1169496
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1169496
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر