Surfaces and Air Bacteriology of Selected Wards at a Referral Hospital, Northwest Ethiopia: A Cross-Sectional Study

المؤلفون المشاركون

Derbie, Awoke
Getachew, Hailu
Mekonnen, Daniel

المصدر

International Journal of Microbiology

العدد

المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2018-05-13

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

الطب البشري

الملخص EN

Background.

The hospital environment is a source of medically important pathogens that are mostly multidrug resistant (MDR) and posing a major therapeutic challenge.

The aim of this study was to assess the surface and air bacteriology of selected wards at Felege Hiwot Referral Hospital (FHRH), Northwest Ethiopia.

Methods.

A cross-sectional study was carried out from 15th February to 30th April 2017.

A total of 356 surface and air samples were collected from selected wards using 5% sheep blood agar (Oxoid, UK) and processed at FHRH microbiology laboratory following the standard bacteriological procedures.

Pure isolates were tested against the recommended antibiotics using Kirby–Bauer disc diffusion methods, and the susceptibility profile was determined based on Clinical Laboratory Standards Institute (CLSI).

Data were entered and analyzed using SPSS version 23 for Windows.

Results.

Of the total 356 samples processed, 274 were from surfaces and 82 were from air.

Among these, 141 (39.6%) showed bacterial growth, yielding a total of 190 isolates.

Gram-positive isolates were predominant at 81.6% (n=155), while the gram negatives were at 18.4% (n=35).

The main isolates were coagulase negative staphylococci (CoNs), 44%, followed by S.

aureus, 37.4%, and Klebsiella species at 11.6%.

The bacterial load on surfaces and air was found beyond the standard limits.

Besides, the antimicrobial susceptibility profile of the isolates showed that about 75% of the identified isolates were found resistant for two and more antimicrobial agents tested.

Conclusions.

This study showed high degree of bacterial load that is beyond the standard limits on both surfaces and air samples of the hospital.

Furthermore, some 75% of the isolates were found multidrug resistant.

Therefore, it is important to evaluate and strengthen the infection prevention practice of the hospital.

Moreover, stakeholders should also reinforce actions to decrease the pressure of antimicrobial resistance in the studied area.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Getachew, Hailu& Derbie, Awoke& Mekonnen, Daniel. 2018. Surfaces and Air Bacteriology of Selected Wards at a Referral Hospital, Northwest Ethiopia: A Cross-Sectional Study. International Journal of Microbiology،Vol. 2018, no. 2018, pp.1-7.
https://search.emarefa.net/detail/BIM-1173373

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Getachew, Hailu…[et al.]. Surfaces and Air Bacteriology of Selected Wards at a Referral Hospital, Northwest Ethiopia: A Cross-Sectional Study. International Journal of Microbiology No. 2018 (2018), pp.1-7.
https://search.emarefa.net/detail/BIM-1173373

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Getachew, Hailu& Derbie, Awoke& Mekonnen, Daniel. Surfaces and Air Bacteriology of Selected Wards at a Referral Hospital, Northwest Ethiopia: A Cross-Sectional Study. International Journal of Microbiology. 2018. Vol. 2018, no. 2018, pp.1-7.
https://search.emarefa.net/detail/BIM-1173373

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1173373