Development of an Amperometric Glucose Biosensor Based on the Immobilization of Glucose Oxidase on the Se-MCM-41 Mesoporous Composite

المؤلفون المشاركون

Yusan, Sabriye
Rahman, Mokhlesur M.
Mohamad, Nasir
Arrif, Tengku M.
Latif, Ahmad Zubaidi A.
M. A., Mohd Aznan
Wan Nik, W. B.

المصدر

Journal of Analytical Methods in Chemistry

العدد

المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-8، 8ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2018-05-10

دولة النشر

مصر

عدد الصفحات

8

التخصصات الرئيسية

الكيمياء

الملخص EN

A new bioenzymatic glucose biosensor for selective and sensitive detection of glucose was developed by the immobilization of glucose oxidase (GOD) onto selenium nanoparticle-mesoporous silica composite (MCM-41) matrix and then prepared as a carbon paste electrode (CPE).

Cyclic voltammetry was employed to probe the catalytic behavior of the biosensor.

A linear calibration plot is obtained over a wide concentration range of glucose from 1 × 10−5 to 2 × 10−3 M.

Under optimal conditions, the biosensor exhibits high sensitivity (0.34 µA·mM−1), low detection limit (1 × 10−4 M), high affinity to glucose (Km = 0.02 mM), and also good reproducibility (R.S.D.

2.8%, n=10) and a stability of about ten days when stored dry at +4°C.

Besides, the effects of pH value, scan rate, mediator effects on the glucose current, and electroactive interference of the biosensor were also discussed.

As a result, the biosensor exhibited an excellent electrocatalytic response to glucose as well as unique stability and reproducibility.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Yusan, Sabriye& Rahman, Mokhlesur M.& Mohamad, Nasir& Arrif, Tengku M.& Latif, Ahmad Zubaidi A.& M. A., Mohd Aznan…[et al.]. 2018. Development of an Amperometric Glucose Biosensor Based on the Immobilization of Glucose Oxidase on the Se-MCM-41 Mesoporous Composite. Journal of Analytical Methods in Chemistry،Vol. 2018, no. 2018, pp.1-8.
https://search.emarefa.net/detail/BIM-1176265

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Yusan, Sabriye…[et al.]. Development of an Amperometric Glucose Biosensor Based on the Immobilization of Glucose Oxidase on the Se-MCM-41 Mesoporous Composite. Journal of Analytical Methods in Chemistry No. 2018 (2018), pp.1-8.
https://search.emarefa.net/detail/BIM-1176265

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Yusan, Sabriye& Rahman, Mokhlesur M.& Mohamad, Nasir& Arrif, Tengku M.& Latif, Ahmad Zubaidi A.& M. A., Mohd Aznan…[et al.]. Development of an Amperometric Glucose Biosensor Based on the Immobilization of Glucose Oxidase on the Se-MCM-41 Mesoporous Composite. Journal of Analytical Methods in Chemistry. 2018. Vol. 2018, no. 2018, pp.1-8.
https://search.emarefa.net/detail/BIM-1176265

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1176265