![](/images/graphics-bg.png)
Harmonic Susceptibility Study of DC Collection Network Based on Frequency Scan and Discrete Time-Domain Modelling Approach
المؤلفون المشاركون
Imbaquingo, Carlos Enrique
Sarrà, Eduard
Isernia, Nicola
Tonellotto, Alberto
Chen, Yu-Hsing
Dincan, Catalin Gabriel
Kjær, Philip
Bak, Claus Leth
Wang, Xiongfei
المصدر
Journal of Electrical and Computer Engineering
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-25، 25ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-12-16
دولة النشر
مصر
عدد الصفحات
25
التخصصات الرئيسية
تكنولوجيا المعلومات وعلم الحاسوب
الملخص EN
The equivalent model of offshore DC power collection network for the harmonic susceptibility study is proposed based on the discrete time-domain modelling technique and frequency scan approach in the frequency domain.
The proposed methodology for modelling a power converter and a DC collection system in the frequency domain can satisfy harmonic studies of any configuration of wind farm network and thereby find suitable design of power components and array network.
The methodology is intended to allow studies on any configuration of the wind power collection, regardless of choice of converter topology, array cable configuration, and control design.
To facilitate harmonic susceptibility study, modelling DC collection network includes creating the harmonic model of the DC turbine converter and modelling the array network.
The current harmonics within the DC collection network are obtained in the frequency domain to identify the resonance frequency of the array network and potential voltage amplification issues, where the harmonic model of the turbine converter is verified by the comparison of the converter switching model in the PLECS™ circuit simulation tool and laboratory test bench, and show a good agreement.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Imbaquingo, Carlos Enrique& Sarrà, Eduard& Isernia, Nicola& Tonellotto, Alberto& Chen, Yu-Hsing& Dincan, Catalin Gabriel…[et al.]. 2018. Harmonic Susceptibility Study of DC Collection Network Based on Frequency Scan and Discrete Time-Domain Modelling Approach. Journal of Electrical and Computer Engineering،Vol. 2018, no. 2018, pp.1-25.
https://search.emarefa.net/detail/BIM-1184356
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Imbaquingo, Carlos Enrique…[et al.]. Harmonic Susceptibility Study of DC Collection Network Based on Frequency Scan and Discrete Time-Domain Modelling Approach. Journal of Electrical and Computer Engineering No. 2018 (2018), pp.1-25.
https://search.emarefa.net/detail/BIM-1184356
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Imbaquingo, Carlos Enrique& Sarrà, Eduard& Isernia, Nicola& Tonellotto, Alberto& Chen, Yu-Hsing& Dincan, Catalin Gabriel…[et al.]. Harmonic Susceptibility Study of DC Collection Network Based on Frequency Scan and Discrete Time-Domain Modelling Approach. Journal of Electrical and Computer Engineering. 2018. Vol. 2018, no. 2018, pp.1-25.
https://search.emarefa.net/detail/BIM-1184356
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1184356
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)