Effect of Cap-Lenticule Diameter Difference on the Visual Outcome and Higher-Order Aberrations in SMILE: 0.4 mm versus 1.0 mm
المؤلفون المشاركون
المصدر
العدد
المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-7، 7ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2017-11-15
دولة النشر
مصر
عدد الصفحات
7
التخصصات الرئيسية
الملخص EN
Purpose.
To evaluate the effect of cap-lenticule diameter difference (CLDD) on the visual outcome and higher-order aberrations (HOAs) of small-incision lenticule extraction (SMILE).
Methods.
A total of 132 patients who had bilateral SMILE for myopia or myopic astigmatism were included.
The CLDD was 0.4 mm in 54 patients (group 1) and 1.0 mm in 78 patients (group 2).
The refractive parameters, uncorrected (UDVA) and corrected distance visual acuity (CDVA), and HOAs were determined preoperatively and during six months follow-up.
Results.
Group 1 had better CDVA (in logMAR) compared to group 2 at day 1 (−0.07 ± 0.07 versus 0.04 ± 0.07, resp.; p<0.001) and week 1 (−0.07 ± 0.07 versus –0.04 ± 0.07, resp.; p=0.001).
The visual acuity improved more in group 1 than in group 2.
The UDVA (in logMAR) was 0.07 ± 0.07 and 0.29 ± 0.09 at day 1 (p<0.001) and −0.08 ± 0.07 and −0.06 ± 0.06 at six months (p=0.038) in group 1 and group 2, respectively.
Group 1 was associated with significantly less induction of HOAs (0.24 ± 0.08 μm and 0.32 ± 0.26 μm, resp.; p=0.002).
Conclusions.
In SMILE, 0.4 mm CLDD is associated with better visual outcome and less induction of HOAs than 1.0 mm.
Narrow CLDD should be considered in SMILE to increase the visual acuity particularly in the early postoperative period.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Torun Acar, Banu& Acar, Suphi. 2017. Effect of Cap-Lenticule Diameter Difference on the Visual Outcome and Higher-Order Aberrations in SMILE: 0.4 mm versus 1.0 mm. Journal of Ophthalmology،Vol. 2017, no. 2017, pp.1-7.
https://search.emarefa.net/detail/BIM-1185458
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Torun Acar, Banu& Acar, Suphi. Effect of Cap-Lenticule Diameter Difference on the Visual Outcome and Higher-Order Aberrations in SMILE: 0.4 mm versus 1.0 mm. Journal of Ophthalmology No. 2017 (2017), pp.1-7.
https://search.emarefa.net/detail/BIM-1185458
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Torun Acar, Banu& Acar, Suphi. Effect of Cap-Lenticule Diameter Difference on the Visual Outcome and Higher-Order Aberrations in SMILE: 0.4 mm versus 1.0 mm. Journal of Ophthalmology. 2017. Vol. 2017, no. 2017, pp.1-7.
https://search.emarefa.net/detail/BIM-1185458
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1185458
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر