Evaluation of Bleb Morphology and Reduction in IOP and Glaucoma Medication following Implantation of a Novel Gel Stent
المؤلفون المشاركون
Cannizzo, Paola Maria Loredana
Consolandi, Giulia
Lavia, Carlo Alessandro
Fea, Antonio M.
Rolle, Teresa
Aragno, Vittoria
Spinetta, Roberta
Germinetti, Francesco
المصدر
العدد
المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-9، 9ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2017-06-20
دولة النشر
مصر
عدد الصفحات
9
التخصصات الرئيسية
الملخص EN
Objective.
To evaluate the efficacy and safety of the Xen Gel Stent and provide a macro- and microscopic analyses of bleb morphology.
Methods.
A prospective 12-month study on patients with primary open-angle glaucoma.
Patients underwent implantation of the XEN Gel Stent (Allergan INC, Dublin, Ireland) either alone or combined with a cataract surgery.
Biomicroscopy, in vivo confocal microscopy (IVCM), and anterior segment-optical coherence tomography (AS-OCT) were used to assess bleb morphology.
Safety parameters were adverse events, best corrected visual acuity, visual field, and corneal endothelial cell loss.
A postoperative IOP ≤ 18 mmHg without or on medications was respectively defined as complete and qualified success while an IOP ≥ 18 mmHg was defined as failure.
Results.
Twelve eyes of 11 patients were evaluated.
At one year, 5 out of 10 patients available achieved a complete success while five were qualified success.
AS-OCT showed that bleb wall reflectivity was significantly higher in the failure group; IVCM revealed that stromal density was significantly lower in the success group.
No safety issues were recorded.
Conclusion.
Implantation of the XEN Gel Stent appears to be a safe and effective procedure.
AS-OCT and IVCM may be helpful in bleb assessment.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Fea, Antonio M.& Spinetta, Roberta& Cannizzo, Paola Maria Loredana& Consolandi, Giulia& Lavia, Carlo Alessandro& Aragno, Vittoria…[et al.]. 2017. Evaluation of Bleb Morphology and Reduction in IOP and Glaucoma Medication following Implantation of a Novel Gel Stent. Journal of Ophthalmology،Vol. 2017, no. 2017, pp.1-9.
https://search.emarefa.net/detail/BIM-1185633
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Fea, Antonio M.…[et al.]. Evaluation of Bleb Morphology and Reduction in IOP and Glaucoma Medication following Implantation of a Novel Gel Stent. Journal of Ophthalmology No. 2017 (2017), pp.1-9.
https://search.emarefa.net/detail/BIM-1185633
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Fea, Antonio M.& Spinetta, Roberta& Cannizzo, Paola Maria Loredana& Consolandi, Giulia& Lavia, Carlo Alessandro& Aragno, Vittoria…[et al.]. Evaluation of Bleb Morphology and Reduction in IOP and Glaucoma Medication following Implantation of a Novel Gel Stent. Journal of Ophthalmology. 2017. Vol. 2017, no. 2017, pp.1-9.
https://search.emarefa.net/detail/BIM-1185633
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1185633
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر