Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects
المؤلفون المشاركون
المصدر
العدد
المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-9، 9ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2017-01-30
دولة النشر
مصر
عدد الصفحات
9
التخصصات الرئيسية
الملخص EN
Background.
Blood pulsation affects the results obtained using various medical devices in many different ways.
Method.
The paper proves the effect of blood pulsation on intraocular pressure measurements.
Six measurements for each of the 10 healthy subjects were performed in various phases of blood pulsation.
A total of 8400 corneal deformation images were recorded.
The results of intraocular pressure measurements were related to the results of heartbeat phases measured with a pulse oximeter placed on the index finger of the subject’s left hand.
Results.
The correlation between the heartbeat phase measured with a pulse oximeter and intraocular pressure is 0.69±0.26 (p<0.05).
The phase shift calculated for the maximum correlation is equal to 60±40° (p<0.05).
When the moment of measuring intraocular pressure with an air-puff tonometer is not synchronized, the changes in IOP for the analysed group of subjects can vary in the range of ±2.31 mmHg (p<0.3).
Conclusions.
Blood pulsation has a statistically significant effect on the results of intraocular pressure measurement.
For this reason, in modern ophthalmic devices, the measurement should be synchronized with the heartbeat phases.
The paper proposes an additional method for synchronizing the time of pressure measurement with the blood pulsation phase.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Koprowski, Robert& Tian, Lei. 2017. Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects. Journal of Ophthalmology،Vol. 2017, no. 2017, pp.1-9.
https://search.emarefa.net/detail/BIM-1185690
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Koprowski, Robert& Tian, Lei. Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects. Journal of Ophthalmology No. 2017 (2017), pp.1-9.
https://search.emarefa.net/detail/BIM-1185690
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Koprowski, Robert& Tian, Lei. Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects. Journal of Ophthalmology. 2017. Vol. 2017, no. 2017, pp.1-9.
https://search.emarefa.net/detail/BIM-1185690
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1185690
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر