Intraocular Pressure Changes during Femtosecond Laser-Assisted Cataract Surgery: A Comparison between Two Different Patient Interfaces

المؤلفون المشاركون

De Giacinto, Chiara
D’Aloisio, Rossella
Tognetto, Daniele
Candian, Tommaso
Perrotta, Alberto Armando
Bova, Alessandro

المصدر

Journal of Ophthalmology

العدد

المجلد 2019، العدد 2019 (31 ديسمبر/كانون الأول 2019)، ص ص. 1-5، 5ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2019-09-25

دولة النشر

مصر

عدد الصفحات

5

التخصصات الرئيسية

الطب البشري

الملخص EN

Purpose.

The aim of this retrospective cohort study was to evaluate intraocular pressure (IOP) changes during femtosecond laser-assisted cataract surgery (FLACS) using two different patient interface systems.

Methods.

116 eyes of 116 patients scheduled for cataract surgery were divided into 2 groups: group 1 (61 eyes) and group 2 (55 eyes) underwent FLACS using Catalys Laser with fluid interface (liquid optics interface, LOI) and LenSx Laser with curved interface and soft contact lens (SoftFit), respectively.

IOP was assessed using a portable rebound tonometer (Icare®) preoperatively, after docking, immediately after surgery, at one and seven days postoperatively.

Results.

In group 1, the mean IOP (±SD) was 14.1 ± 0.4 mmHg before surgery, 33.2 ± 1.1 mmHg after docking, and 21.4 ± 0.9 mmHg immediately after surgery.

In group 2, the mean IOP was 13.8 ± 0.4 mmHg before surgery, 24.2 ± 1.4 mmHg after docking, and 20.2 ± 1.2 mmHg immediately after surgery.

After the docking procedure, a statistically significant increase in IOP from the baseline was found in both groups (p<0.001).

Moreover, no statistically significant difference in IOP measured at 1 and 7 days postoperatively was observed compared with the preoperative values (p>0.05) using both laser platforms.

No intraoperative and postoperative complications were observed.

Conclusions.

FLACS suction phase resulted in a transient increase of IOP in both groups, especially with the LOI system, and it is probably related to the greater pressure of a suction ring and suction generated through the vacuum, independently from the effect of femtosecond laser itself.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

De Giacinto, Chiara& D’Aloisio, Rossella& Bova, Alessandro& Candian, Tommaso& Perrotta, Alberto Armando& Tognetto, Daniele. 2019. Intraocular Pressure Changes during Femtosecond Laser-Assisted Cataract Surgery: A Comparison between Two Different Patient Interfaces. Journal of Ophthalmology،Vol. 2019, no. 2019, pp.1-5.
https://search.emarefa.net/detail/BIM-1185930

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

De Giacinto, Chiara…[et al.]. Intraocular Pressure Changes during Femtosecond Laser-Assisted Cataract Surgery: A Comparison between Two Different Patient Interfaces. Journal of Ophthalmology No. 2019 (2019), pp.1-5.
https://search.emarefa.net/detail/BIM-1185930

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

De Giacinto, Chiara& D’Aloisio, Rossella& Bova, Alessandro& Candian, Tommaso& Perrotta, Alberto Armando& Tognetto, Daniele. Intraocular Pressure Changes during Femtosecond Laser-Assisted Cataract Surgery: A Comparison between Two Different Patient Interfaces. Journal of Ophthalmology. 2019. Vol. 2019, no. 2019, pp.1-5.
https://search.emarefa.net/detail/BIM-1185930

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1185930