Kinematic Calibration of a Parallel 2-UPSRRR Ankle Rehabilitation Robot

المؤلفون المشاركون

Kong, Yuan
Dong, Mingjie
Li, Jianfeng
Fan, Wenpei

المصدر

Journal of Healthcare Engineering

العدد

المجلد 2020، العدد 2020 (31 ديسمبر/كانون الأول 2020)، ص ص. 1-12، 12ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2020-09-03

دولة النشر

مصر

عدد الصفحات

12

التخصصات الرئيسية

الصحة العامة
الطب البشري

الملخص EN

In order to better perform rehabilitation training on the ankle joint complex in the direction of dorsiflexion/plantarflexion and inversion/eversion, especially when performing the isokinetic muscle strength exercise, we need to calibrate the kinematic model to improve its control precision.

The ankle rehabilitation robot we develop is a parallel mechanism, with its movements in the two directions driven by two linear motors.

Inverse solution of positions is deduced and the output lengths of the two UPS kinematic branches are calibrated in the directions of dorsiflexion, plantarflexion, inversion, and eversion, respectively.

Motion of each branch in different directions is fitted in high-order form according to experimental data.

Variances, standard deviation, and goodness of fit are taken into consideration when choosing the best fitting curve, which ensures that each calibration can match the most appropriate fitting curve.

Experiments are conducted to verify the effectiveness of the kinematic calibration after finishing the calibration, and the errors before and after calibration of the two kinematic chains in different directions are compared, respectively, which shows that the accuracy after calibration has been significantly improved.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Dong, Mingjie& Kong, Yuan& Li, Jianfeng& Fan, Wenpei. 2020. Kinematic Calibration of a Parallel 2-UPSRRR Ankle Rehabilitation Robot. Journal of Healthcare Engineering،Vol. 2020, no. 2020, pp.1-12.
https://search.emarefa.net/detail/BIM-1186240

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Dong, Mingjie…[et al.]. Kinematic Calibration of a Parallel 2-UPSRRR Ankle Rehabilitation Robot. Journal of Healthcare Engineering No. 2020 (2020), pp.1-12.
https://search.emarefa.net/detail/BIM-1186240

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Dong, Mingjie& Kong, Yuan& Li, Jianfeng& Fan, Wenpei. Kinematic Calibration of a Parallel 2-UPSRRR Ankle Rehabilitation Robot. Journal of Healthcare Engineering. 2020. Vol. 2020, no. 2020, pp.1-12.
https://search.emarefa.net/detail/BIM-1186240

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1186240