Wearable Active Electrode for sEMG Monitoring Using Two-Channel Brass Dry Electrodes with Reduced Electronics

المؤلفون المشاركون

Leija, L.
Ruvalcaba, J. Antonio
Gutiérrez, M. I.
Vera, A.

المصدر

Journal of Healthcare Engineering

العدد

المجلد 2020، العدد 2020 (31 ديسمبر/كانون الأول 2020)، ص ص. 1-11، 11ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2020-08-01

دولة النشر

مصر

عدد الصفحات

11

التخصصات الرئيسية

الصحة العامة
الطب البشري

الملخص EN

Gel-based electrodes are employed to record sEMG signals for prolonged periods.

These signals are used for the control of myoelectric prostheses, clinical analysis, or sports medicine.

However, when the gel dries, the electrode-skin impedance increases considerably.

Using dry active electrodes (AEs) to compensate variations of impedance is an alternative for long-term recording.

This work describes the optimization of the electronic design of a conventional AE by removing the impedance coupling stage and two filters.

The proposed work consisted of 5 stages: electrodes, amplification (X250), 2.2 Vdc offset, low-pass filter, and ADC with USART communication.

The device did not need the use of electrolytic gel.

The measurements of CMRR (96 dB), amplitude of the output sEMG signal (∼1.6 Vp-p), and system bandwidth (15–450 Hz) were performed in order to confirm the reliability of the device as an sEMG signal acquisition system.

The SNR values from seven movements performed by eleven volunteers were compared in order to measure the repeatability of the measurements (average 30.32 dB for a wrist flexion).

The SNR for wrist flexion measured with the proposed and the commercial system was compared; the values were 49 dB and 60 dB, respectively.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Ruvalcaba, J. Antonio& Gutiérrez, M. I.& Vera, A.& Leija, L.. 2020. Wearable Active Electrode for sEMG Monitoring Using Two-Channel Brass Dry Electrodes with Reduced Electronics. Journal of Healthcare Engineering،Vol. 2020, no. 2020, pp.1-11.
https://search.emarefa.net/detail/BIM-1186285

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Ruvalcaba, J. Antonio…[et al.]. Wearable Active Electrode for sEMG Monitoring Using Two-Channel Brass Dry Electrodes with Reduced Electronics. Journal of Healthcare Engineering No. 2020 (2020), pp.1-11.
https://search.emarefa.net/detail/BIM-1186285

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Ruvalcaba, J. Antonio& Gutiérrez, M. I.& Vera, A.& Leija, L.. Wearable Active Electrode for sEMG Monitoring Using Two-Channel Brass Dry Electrodes with Reduced Electronics. Journal of Healthcare Engineering. 2020. Vol. 2020, no. 2020, pp.1-11.
https://search.emarefa.net/detail/BIM-1186285

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1186285