![](/images/graphics-bg.png)
Optimization of Echo Views for Percutaneous Device Closure of Pediatric Atrial Septal Defect through the Femoral Vein Guided by Transthoracic Echocardiography without Radiation
المؤلفون المشاركون
Ma, Ning
Zhang, Hongju
Li, Pei
Ye, Zankai
Li, Zhiqiang
Yi, Hanlu
Zhu, Yaobin
Sun, Yan
المصدر
Journal of Interventional Cardiology
العدد
المجلد 2020، العدد 2020 (31 ديسمبر/كانون الأول 2020)، ص ص. 1-5، 5ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2020-10-31
دولة النشر
مصر
عدد الصفحات
5
التخصصات الرئيسية
الملخص EN
Objectives.
This study aimed to explore the selection of views for transthoracic echocardiography-guided transfemoral puncture for the device closure of pediatric atrial septal defect (ASD) without radiation.
Methods.
Sixty children (29 males and 31 females) were diagnosed with a central ASD, normal heart function, and no other intracardiac deformity.
All procedures were performed in a surgical operating room (without radiological equipment) under basic anesthesia; the femoral vein pathway and guidance by only transthoracic echocardiography were used to complete the device closure of the ASD.
The subcostal acoustic window and parasternal aorta short-axis views were used to guide the extra stiff wire and catheter into the left atrium.
All procedures were performed under the subcostal biatrial section.
The sheath entered the left atrium, and the apical four-chamber view was used to monitor the delivery and release of the occluder.
Results.
Successful closure of the ASD was achieved in all cases.
The operating time from the end of the puncture to the release of the occluder was 10.36 ± 3.57 minutes.
No other incisions were needed in 60 cases.
No occluders were removed, and no residual shunt or pericardial effusions were detected after the procedures, during the non-ICU stay time.
The average hospital stay was 2.19 ± 0.58 days.
Conclusion.
The accurate selection of transthoracic echocardiographic views can better ensure the safety and effectiveness of ASD closure through the femoral vein without radiation in children.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Ye, Zankai& Li, Zhiqiang& Yi, Hanlu& Zhu, Yaobin& Sun, Yan& Zhang, Hongju…[et al.]. 2020. Optimization of Echo Views for Percutaneous Device Closure of Pediatric Atrial Septal Defect through the Femoral Vein Guided by Transthoracic Echocardiography without Radiation. Journal of Interventional Cardiology،Vol. 2020, no. 2020, pp.1-5.
https://search.emarefa.net/detail/BIM-1187871
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Ye, Zankai…[et al.]. Optimization of Echo Views for Percutaneous Device Closure of Pediatric Atrial Septal Defect through the Femoral Vein Guided by Transthoracic Echocardiography without Radiation. Journal of Interventional Cardiology No. 2020 (2020), pp.1-5.
https://search.emarefa.net/detail/BIM-1187871
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Ye, Zankai& Li, Zhiqiang& Yi, Hanlu& Zhu, Yaobin& Sun, Yan& Zhang, Hongju…[et al.]. Optimization of Echo Views for Percutaneous Device Closure of Pediatric Atrial Septal Defect through the Femoral Vein Guided by Transthoracic Echocardiography without Radiation. Journal of Interventional Cardiology. 2020. Vol. 2020, no. 2020, pp.1-5.
https://search.emarefa.net/detail/BIM-1187871
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1187871
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)