Efficacy of Manual Hemostasis for Percutaneous Axillary Artery Intra-Aortic Balloon Pump Removal
المؤلفون المشاركون
Okoh, Alexis
Kaki, Amir
Sossou, Christoph
Tayal, Rajiv
DiVita, Michael
Stelling, Kelly
McCabe, James M.
Wasty, Najam
Baran, David A.
المصدر
Journal of Interventional Cardiology
العدد
المجلد 2020، العدد 2020 (31 ديسمبر/كانون الأول 2020)، ص ص. 1-4، 4ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2020-07-26
دولة النشر
مصر
عدد الصفحات
4
التخصصات الرئيسية
الملخص EN
Background.
The prevalence of peripheral vascular disease has led to the re-emergence of percutaneous axillary vascular access as a suitable alternative access site to femoral artery.
We sought to investigate the efficacy and safety of manual hemostasis in the axillary artery.
Methods.
Data were collected from a prospective internal registry of patients who had a Maquet® (Rastatt, Germany) Mega 50 cc intra-aortic balloon pumps (IABP) placed in the axillary artery position.
They were anticoagulated with weight-based intravenous heparin to maintain an activated partial thromboplastin time (aPTT) of 50–80 seconds.
Anticoagulation was discontinued 2 hours prior to the device explantation.
Manual compression was used to achieve the hemostasis of the axillary artery.
Vascular and bleeding complications attributable to manual hemostasis were classified based on the Valve Academic Research Consortium-2 (VARC-2) and Bleeding Academic Research Consortium-2 (BARC-2) classifications, respectively.
Results.
29 of 46 patients (63%) achieved axillary artery homeostasis via manual compression.
The median duration of IABP implantation was 12 days (range 1–54 days).
Median compression time was 20 minutes (range 5–60 minutes).
There were no major vascular or bleeding complications as defined by the VARC-2 and BARC-2 criteria, respectively.
Conclusion.
Manual compression of the axillary artery appears to be an effective and safe method for achieving hemostasis.
Large prospective randomized control trials may be needed to corroborate these findings.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Tayal, Rajiv& DiVita, Michael& Sossou, Christoph& Okoh, Alexis& Stelling, Kelly& McCabe, James M.…[et al.]. 2020. Efficacy of Manual Hemostasis for Percutaneous Axillary Artery Intra-Aortic Balloon Pump Removal. Journal of Interventional Cardiology،Vol. 2020, no. 2020, pp.1-4.
https://search.emarefa.net/detail/BIM-1187879
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Tayal, Rajiv…[et al.]. Efficacy of Manual Hemostasis for Percutaneous Axillary Artery Intra-Aortic Balloon Pump Removal. Journal of Interventional Cardiology No. 2020 (2020), pp.1-4.
https://search.emarefa.net/detail/BIM-1187879
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Tayal, Rajiv& DiVita, Michael& Sossou, Christoph& Okoh, Alexis& Stelling, Kelly& McCabe, James M.…[et al.]. Efficacy of Manual Hemostasis for Percutaneous Axillary Artery Intra-Aortic Balloon Pump Removal. Journal of Interventional Cardiology. 2020. Vol. 2020, no. 2020, pp.1-4.
https://search.emarefa.net/detail/BIM-1187879
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1187879
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر