NPC Three-Level Inverter Open-Circuit Fault Diagnosis Based on Adaptive Electrical Period Partition and Random Forest

المؤلفون المشاركون

Liu, Shiyuan
Qian, Xu
Wan, Hong
Ye, Zongbin
Wu, Shoupeng
Ren, Xiaohong

المصدر

Journal of Sensors

العدد

المجلد 2020، العدد 2020 (31 ديسمبر/كانون الأول 2020)، ص ص. 1-18، 18ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2020-01-17

دولة النشر

مصر

عدد الصفحات

18

التخصصات الرئيسية

هندسة مدنية

الملخص EN

Fault detection can increase the reliability and efficiency of power electronic converters employed in power systems.

Among the converters in the power system, a Neutral Point Clamped (NPC) three-level inverter is most commonly used to drive electric motors.

In this paper, a new approach for open-circuit fault detection and location of the NPC three-level inverter for a shifting process using a constant voltage-to-frequency ratio is proposed.

In order to diagnose open-circuit fault in as short a time as possible, an adaptive electrical period partition (AEPP) algorithm is proposed to pick single electrical periods from real-time three-phase current signals.

The Maximal Overlap Discrete Wavelet Transformation (MODWT) and Park’s Vector Modulus (PVM) are used for feature analysis and normalization of electrical period signals.

The statistical characteristics of the electrical period signals are extracted, and a random forest model is constructed to realize the state classification.

Compared with the traditional fault diagnosis method, the proposed algorithm finds fault locations quickly and accurately.

The effectiveness and accuracy of the proposed algorithm are verified by experiments.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Liu, Shiyuan& Qian, Xu& Wan, Hong& Ye, Zongbin& Wu, Shoupeng& Ren, Xiaohong. 2020. NPC Three-Level Inverter Open-Circuit Fault Diagnosis Based on Adaptive Electrical Period Partition and Random Forest. Journal of Sensors،Vol. 2020, no. 2020, pp.1-18.
https://search.emarefa.net/detail/BIM-1190719

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Liu, Shiyuan…[et al.]. NPC Three-Level Inverter Open-Circuit Fault Diagnosis Based on Adaptive Electrical Period Partition and Random Forest. Journal of Sensors No. 2020 (2020), pp.1-18.
https://search.emarefa.net/detail/BIM-1190719

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Liu, Shiyuan& Qian, Xu& Wan, Hong& Ye, Zongbin& Wu, Shoupeng& Ren, Xiaohong. NPC Three-Level Inverter Open-Circuit Fault Diagnosis Based on Adaptive Electrical Period Partition and Random Forest. Journal of Sensors. 2020. Vol. 2020, no. 2020, pp.1-18.
https://search.emarefa.net/detail/BIM-1190719

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل