![](/images/graphics-bg.png)
A Correction Method for UAV Helicopter Airborne Temperature and Humidity Sensor
المؤلفون المشاركون
Fan, Longqing
Chen, Ge
Yu, Fangjie
Liu, Yunfei
Li, Linhua
المصدر
Mathematical Problems in Engineering
العدد
المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-11، 11ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2017-05-07
دولة النشر
مصر
عدد الصفحات
11
التخصصات الرئيسية
الملخص EN
This paper presents a correction method for UAV helicopter airborne temperature and humidity including an error correction scheme and a bias-calibration scheme.
As rotor downwash flow brings measurement error on helicopter airborne sensors inevitably, the error correction scheme constructs a model between the rotor induced velocity and temperature and humidity by building the heat balance equation for platinum resistor temperature sensor and the pressure correction term for humidity sensor.
The induced velocity of a spatial point below the rotor disc plane can be calculated by the sum of the induced velocities excited by center line vortex, rotor disk vortex, and skew cylinder vortex based on the generalized vortex theory.
In order to minimize the systematic biases, the bias-calibration scheme adopts a multiple linear regression to achieve a systematically consistent result with the tethered balloon profiles.
Two temperature and humidity sensors were mounted on “Z-5” UAV helicopter in the field experiment.
Overall, the result of applying the calibration method shows that the temperature and relative humidity obtained by UAV helicopter closely align with tethered balloon profiles in providing measurements of the temperature profiles and humidity profiles within marine atmospheric boundary layers.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Fan, Longqing& Chen, Ge& Yu, Fangjie& Liu, Yunfei& Li, Linhua. 2017. A Correction Method for UAV Helicopter Airborne Temperature and Humidity Sensor. Mathematical Problems in Engineering،Vol. 2017, no. 2017, pp.1-11.
https://search.emarefa.net/detail/BIM-1192660
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Fan, Longqing…[et al.]. A Correction Method for UAV Helicopter Airborne Temperature and Humidity Sensor. Mathematical Problems in Engineering No. 2017 (2017), pp.1-11.
https://search.emarefa.net/detail/BIM-1192660
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Fan, Longqing& Chen, Ge& Yu, Fangjie& Liu, Yunfei& Li, Linhua. A Correction Method for UAV Helicopter Airborne Temperature and Humidity Sensor. Mathematical Problems in Engineering. 2017. Vol. 2017, no. 2017, pp.1-11.
https://search.emarefa.net/detail/BIM-1192660
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1192660
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)