Evaluation of the Coating with TiO2 Nanoparticles as an Option for the Improvement of the Characteristics of NiTi Archwires: Histopathological, Cytotoxic, and Genotoxic Evidence

المؤلفون المشاركون

Morán-Martínez, Javier
Carranza-Rosales, Pilar
Beltrán del Río-Parra, Roberto
Betancourt-Martínez, Nadia Denys
García-Garza, Rubén
Jiménez-Villarreal, Joel
Niño-Castañeda, María Soñadora
Nava-Rivera, Lydia Enith
Facio Umaña, José Alfredo
Arellano Pérez-Vertti, Rubén Daniel

المصدر

Journal of Nanomaterials

العدد

المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-11، 11ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2018-05-06

دولة النشر

مصر

عدد الصفحات

11

التخصصات الرئيسية

الكيمياء
هندسة مدنية

الملخص EN

For the EPD, different voltages and different times were used.

Male rats were used in four groups (n=3) with different treatments.

The blood sample was obtained for genotoxic analysis and liver and kidney organs were removed for histopathological analysis.

The amount of NPs TiO2 deposited on the samples of the arches increases gradually in the times of 15 and 30 s.

At all voltages, however, at 45, 60, 75, and 90 s, there is an increase up to 25 V.

Cell viability in lymphocytes treated with TiO2 NPs did not cause genotoxicity.

In the histopathological findings of hepatic and renal tissue, nuclear alterations and necrosis were observed.

The objective of the study was to improve the physical and biocompatibility characteristics of the NiTi arches for which the EPD is used.

The technique for the deposition of TiO2 NPs was used, where this technique could be used as an economical and versatile way to perform homogeneous depositions even on surfaces with the complexity of the NiTi alloy.

As for genotoxicity and cytotoxicity, we continue to have controversial results.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Morán-Martínez, Javier& Beltrán del Río-Parra, Roberto& Betancourt-Martínez, Nadia Denys& García-Garza, Rubén& Jiménez-Villarreal, Joel& Niño-Castañeda, María Soñadora…[et al.]. 2018. Evaluation of the Coating with TiO2 Nanoparticles as an Option for the Improvement of the Characteristics of NiTi Archwires: Histopathological, Cytotoxic, and Genotoxic Evidence. Journal of Nanomaterials،Vol. 2018, no. 2018, pp.1-11.
https://search.emarefa.net/detail/BIM-1193931

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Morán-Martínez, Javier…[et al.]. Evaluation of the Coating with TiO2 Nanoparticles as an Option for the Improvement of the Characteristics of NiTi Archwires: Histopathological, Cytotoxic, and Genotoxic Evidence. Journal of Nanomaterials No. 2018 (2018), pp.1-11.
https://search.emarefa.net/detail/BIM-1193931

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Morán-Martínez, Javier& Beltrán del Río-Parra, Roberto& Betancourt-Martínez, Nadia Denys& García-Garza, Rubén& Jiménez-Villarreal, Joel& Niño-Castañeda, María Soñadora…[et al.]. Evaluation of the Coating with TiO2 Nanoparticles as an Option for the Improvement of the Characteristics of NiTi Archwires: Histopathological, Cytotoxic, and Genotoxic Evidence. Journal of Nanomaterials. 2018. Vol. 2018, no. 2018, pp.1-11.
https://search.emarefa.net/detail/BIM-1193931

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1193931