Research on the Normal Use of a Plug Discharge Tunnel

المؤلفون المشاركون

Tian, Zhong
Liu, Wen
Deng, Jun
Zhang, Faxing

المصدر

Mathematical Problems in Engineering

العدد

المجلد 2020، العدد 2020 (31 ديسمبر/كانون الأول 2020)، ص ص. 1-12، 12ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2020-02-12

دولة النشر

مصر

عدد الصفحات

12

التخصصات الرئيسية

هندسة مدنية

الملخص EN

This study analyzed the normal use of an unusual flood-releasing tunnel with a plug dissipator.

Firstly, normal physical model tests based on the Froude criterion (1 : 50) were finished.

Secondly, depression physical model tests based on the Froude criterion (1 : 50) and cavitation similarity criterion were finished.

Thirdly, 3-dimensional numerical simulation of flow field was finished, and free surface profile was captured, which was based on RNG k-ε two-equation turbulence model and VOF method.

The focus of this study is on the relationship between normal use and cavitation characteristics (e.g., pressure, turbulence kinetic energy, and cavitation number).

The results show that lowering the reservoir water level, reduced by 20.41 m at most, increases the risk of cavitation of a plug discharge tunnel, which means with the decrease of the flow cavitation number, the possibility of structural damage will increase dramatically, while reducing the outlet height can effectively raise the flow cavitation number, ensuring the safety of normal use.

Under the conditions of free outflow, for the H1/e values of 4.45, 4.00, and 3.55, the conditions in which the tunnel meets the requirements of anticavitation are h/D ≤ 0.42, h/D ≤ 0.39, and h/D ≤ 0.35, respectively.

In addition, the discharge capacity of the tunnel is not significantly reduced with the lowering of outlet height, implying that operation under a low water head of the plug discharge tunnel, as low as 3.55 of H1/e in the test, is feasible.

The results obtained in this study can serve as reference information in engineering design of the plug discharge tunnel.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Liu, Wen& Deng, Jun& Tian, Zhong& Zhang, Faxing. 2020. Research on the Normal Use of a Plug Discharge Tunnel. Mathematical Problems in Engineering،Vol. 2020, no. 2020, pp.1-12.
https://search.emarefa.net/detail/BIM-1195251

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Liu, Wen…[et al.]. Research on the Normal Use of a Plug Discharge Tunnel. Mathematical Problems in Engineering No. 2020 (2020), pp.1-12.
https://search.emarefa.net/detail/BIM-1195251

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Liu, Wen& Deng, Jun& Tian, Zhong& Zhang, Faxing. Research on the Normal Use of a Plug Discharge Tunnel. Mathematical Problems in Engineering. 2020. Vol. 2020, no. 2020, pp.1-12.
https://search.emarefa.net/detail/BIM-1195251

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1195251