![](/images/graphics-bg.png)
Comparisons of Visual and Surgical Outcomes after Reuse or Replacement of Dislocated in-the-Bag Intraocular Lens
المؤلفون المشاركون
Oshitari, Toshiyuki
Baba, Takayuki
Nizawa, Tomohiro
Yamamoto, Shuichi
المصدر
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-4، 4ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-03-28
دولة النشر
مصر
عدد الصفحات
4
التخصصات الرئيسية
الملخص EN
Purpose.
To compare the visual and surgical outcomes after a reuse or a replacement of a dislocated in-the-bag intraocular lens (IOL).
Methods.
This was a retrospective, nonrandomized case series at a single ophthalmological institution.
Cases with an in-the-bag dislocation of an IOL were treated by pars plana vitrectomy and the reuse or the replacement of the IOL.
The lens was held by intrascleral fixation of the haptics of the IOL under both conditions.
The same dislocated IOL was reused in 6 eyes (group A) or it was replaced with another IOL in the other 9 eyes (group B).
The pre- and postoperative parameters analyzed included the visual acuity, refractive error, corneal endothelial cell density, and intraocular pressure (IOP).
Results.
There was no significant difference between the two groups in the postoperative visual acuity (P=0.388), refractive error (P=0.955), IOP (P=0.529), and endothelial cell loss (P=0.940).
A breakage or a tilting of the IOL was observed and required replacement in three eyes in the reuse group (P=0.044).
Conclusions.
Half of the cases with reused in-the-bag dislocated IOL had a breakage or a tilting of the IOL.
The replacement of the in-the-bag dislocated IOL is better than the reuse of the IOL with intrascleral haptics fixation.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Baba, Takayuki& Nizawa, Tomohiro& Oshitari, Toshiyuki& Yamamoto, Shuichi. 2018. Comparisons of Visual and Surgical Outcomes after Reuse or Replacement of Dislocated in-the-Bag Intraocular Lens. Journal of Ophthalmology،Vol. 2018, no. 2018, pp.1-4.
https://search.emarefa.net/detail/BIM-1196852
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Baba, Takayuki…[et al.]. Comparisons of Visual and Surgical Outcomes after Reuse or Replacement of Dislocated in-the-Bag Intraocular Lens. Journal of Ophthalmology No. 2018 (2018), pp.1-4.
https://search.emarefa.net/detail/BIM-1196852
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Baba, Takayuki& Nizawa, Tomohiro& Oshitari, Toshiyuki& Yamamoto, Shuichi. Comparisons of Visual and Surgical Outcomes after Reuse or Replacement of Dislocated in-the-Bag Intraocular Lens. Journal of Ophthalmology. 2018. Vol. 2018, no. 2018, pp.1-4.
https://search.emarefa.net/detail/BIM-1196852
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1196852
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)