Development and Integration of a CO Detection System Based on Wavelength Modulation Spectroscopy Using Near-Infrared DFB Laser
المؤلفون المشاركون
Li, Bin
Zhang, Shuo-Cheng
Chi, Yao-Dan
المصدر
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-01-17
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
A wavelength modulation spectroscopy- (WMS-) based gas sensing system was established to measure concentration of carbon monoxide (CO) in the range 0–100%.
The CO absorption line at 1563.06 nm was scanned with a tunable distributed feedback (DFB) laser, and two InGaAs photodiodes were applied to perform optic-electric conversion.
Without using commercial instruments, essential electrical circuits were self-developed and integrated, including laser temperature controller, laser current driver, signal generator, and digital lock-in amplifier.
The gas cell deployed in the system was fiber coupled with a total effective optical path length of 50 cm.
The second-order harmonic signal was extracted, and experiments of gas detection were carried out to investigate the performance of the sensor, including detection repeatability, detection accuracy, response time, and limit of detection (LoD).
Experiment results show that the sensor is reliable and has acceptable probing performance.
The maximum relative detection error is less than 3.8%, suggesting good detection stability.
Benefiting from the self-developed sensor, the whole CO detection system has small size, affordable expense, and application potential.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Li, Bin& Zhang, Shuo-Cheng& Chi, Yao-Dan. 2018. Development and Integration of a CO Detection System Based on Wavelength Modulation Spectroscopy Using Near-Infrared DFB Laser. Journal of Spectroscopy،Vol. 2018, no. 2018, pp.1-8.
https://search.emarefa.net/detail/BIM-1202420
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Li, Bin…[et al.]. Development and Integration of a CO Detection System Based on Wavelength Modulation Spectroscopy Using Near-Infrared DFB Laser. Journal of Spectroscopy No. 2018 (2018), pp.1-8.
https://search.emarefa.net/detail/BIM-1202420
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Li, Bin& Zhang, Shuo-Cheng& Chi, Yao-Dan. Development and Integration of a CO Detection System Based on Wavelength Modulation Spectroscopy Using Near-Infrared DFB Laser. Journal of Spectroscopy. 2018. Vol. 2018, no. 2018, pp.1-8.
https://search.emarefa.net/detail/BIM-1202420
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1202420
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر