CFD Analysis of a Decay Tank and a Siphon Breaker for an Innovative Integrated Passive Safety System for a Research Reactor

المؤلفون المشاركون

Lee, Kwon-Yeong
Yoon, Hyun-Gi
Park, Dong Kyou

المصدر

Science and Technology of Nuclear Installations

العدد

المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-9، 9ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2017-08-10

دولة النشر

مصر

عدد الصفحات

9

الملخص EN

An innovative integrated passive safety system for a research reactor is proposed in this study to improve the safety of the research reactor.

This integrated system has three functions in the facility as a decay tank, siphon breaker, and long-term cooling tank.

This paper also deals with the process of designing and optimizing the decay tank and the siphon breaker of the integrated passive safety system.

At first, the decay tank was designed and improved step by step, while considering the computational fluid dynamics analysis results.

Consequently, we could satisfy the design requirements of the decay tank.

In addition, the performance of a new type of siphon breaker that was installed in the final decay tank model was tested.

We designed an 18-inch diameter siphon breaker at the top of the decay tank’s third section, and we could observe the breaking of the siphon that prevented the occurrence of a severe accident in the research reactor.

By locating the siphon breaker at the third section of the decay tank, we could also use the coolant of the front three sections for long-term cooling of the research reactor.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Lee, Kwon-Yeong& Yoon, Hyun-Gi& Park, Dong Kyou. 2017. CFD Analysis of a Decay Tank and a Siphon Breaker for an Innovative Integrated Passive Safety System for a Research Reactor. Science and Technology of Nuclear Installations،Vol. 2017, no. 2017, pp.1-9.
https://search.emarefa.net/detail/BIM-1203639

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Lee, Kwon-Yeong…[et al.]. CFD Analysis of a Decay Tank and a Siphon Breaker for an Innovative Integrated Passive Safety System for a Research Reactor. Science and Technology of Nuclear Installations No. 2017 (2017), pp.1-9.
https://search.emarefa.net/detail/BIM-1203639

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Lee, Kwon-Yeong& Yoon, Hyun-Gi& Park, Dong Kyou. CFD Analysis of a Decay Tank and a Siphon Breaker for an Innovative Integrated Passive Safety System for a Research Reactor. Science and Technology of Nuclear Installations. 2017. Vol. 2017, no. 2017, pp.1-9.
https://search.emarefa.net/detail/BIM-1203639

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1203639