Shielding Verifications for a Gamma Irradiation Facility Considering the Installation of a New Automatic Product Loading System

المؤلفون المشاركون

Mesquita, Amir Zacarias
Rodriguez Gual, Maritza
Ribeiro, Edson
Grossi, Pablo Andrade

المصدر

Science and Technology of Nuclear Installations

العدد

المجلد 2017، العدد 2017 (31 ديسمبر/كانون الأول 2017)، ص ص. 1-6، 6ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2017-10-25

دولة النشر

مصر

عدد الصفحات

6

الملخص EN

A new system has been designed to automatically load the samples to be irradiated at the gamma irradiation facility of the Nuclear Technology Development Centre (CDTN) at Belo Horizonte, Brazil.

The objective of this system is the optimization of the experiments performed at the Gamma Irradiation Laboratory for short-time irradiations without interruption of the irradiator cycles.

The installation of this new system requires the opening of a hole at the labyrinth door to allow the loading of irradiating products.

Due to this alteration on the original design, the door opening into the labyrinth requires shielding verification.

The dose rate with the door open is calculated using Monte Carlo MCNPX v 2.6.0 code.

The Monte Carlo source simulations were validated with experimental measurements of dose rate.

The simulation demonstrated that a hole can be opened at the labyrinth entrance when installing an automatic loading system.

Not only does it comply with dose constraint requirements, but it also complies with national and international standards.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Rodriguez Gual, Maritza& Mesquita, Amir Zacarias& Ribeiro, Edson& Grossi, Pablo Andrade. 2017. Shielding Verifications for a Gamma Irradiation Facility Considering the Installation of a New Automatic Product Loading System. Science and Technology of Nuclear Installations،Vol. 2017, no. 2017, pp.1-6.
https://search.emarefa.net/detail/BIM-1203782

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Rodriguez Gual, Maritza…[et al.]. Shielding Verifications for a Gamma Irradiation Facility Considering the Installation of a New Automatic Product Loading System. Science and Technology of Nuclear Installations No. 2017 (2017), pp.1-6.
https://search.emarefa.net/detail/BIM-1203782

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Rodriguez Gual, Maritza& Mesquita, Amir Zacarias& Ribeiro, Edson& Grossi, Pablo Andrade. Shielding Verifications for a Gamma Irradiation Facility Considering the Installation of a New Automatic Product Loading System. Science and Technology of Nuclear Installations. 2017. Vol. 2017, no. 2017, pp.1-6.
https://search.emarefa.net/detail/BIM-1203782

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1203782