Solid Indeterminate Nodules with a Radiological Stability Suggesting Benignity: A Texture Analysis of Computed Tomography Images Based on the Kurtosis and Skewness of the Nodule Volume Density Histogram

المؤلفون المشاركون

Lopes, Agnaldo José
Borguezan, Bruno Max
Saito, Eduardo Haruo
Higa, Claudio
Silva, Aristófanes Corrêa
Nunes, Rodolfo Acatauassú

المصدر

Pulmonary Medicine

العدد

المجلد 2019، العدد 2019 (31 ديسمبر/كانون الأول 2019)، ص ص. 1-7، 7ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2019-10-07

دولة النشر

مصر

عدد الصفحات

7

التخصصات الرئيسية

الأمراض
الطب البشري

الملخص EN

Background.

The number of incidental findings of pulmonary nodules using imaging methods to diagnose other thoracic or extrathoracic conditions has increased, suggesting the need for in-depth radiological image analyses to identify nodule type and avoid unnecessary invasive procedures.

Objectives.

The present study evaluated solid indeterminate nodules with a radiological stability suggesting benignity (SINRSBs) through a texture analysis of computed tomography (CT) images.

Methods.

A total of 100 chest CT scans were evaluated, including 50 cases of SINRSBs and 50 cases of malignant nodules.

SINRSB CT scans were performed using the same noncontrast enhanced CT protocol and equipment; the malignant nodule data were acquired from several databases.

The kurtosis (KUR) and skewness (SKW) values of these tests were determined for the whole volume of each nodule, and the histograms were classified into two basic patterns: peaks or plateaus.

Results.

The mean (MEN) KUR values of the SINRSBs and malignant nodules were 3.37 ± 3.88 and 5.88 ± 5.11, respectively.

The receiver operating characteristic (ROC) curve showed that the sensitivity and specificity for distinguishing SINRSBs from malignant nodules were 65% and 66% for KUR values >6, respectively, with an area under the curve (AUC) of 0.709 (p<0.0001).

The MEN SKW values of the SINRSBs and malignant nodules were 1.73 ± 0.94 and 2.07 ± 1.01, respectively.

The ROC curve showed that the sensitivity and specificity for distinguishing malignant nodules from SINRSBs were 65% and 66% for SKW values >3.1, respectively, with an AUC of 0.709 (p<0.0001).

An analysis of the peak and plateau histograms revealed sensitivity, specificity, and accuracy values of 84%, 74%, and 79%, respectively.

Conclusions.

KUR, SKW, and histogram shape can help to noninvasively diagnose SINRSBs but should not be used alone or without considering clinical data.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Borguezan, Bruno Max& Lopes, Agnaldo José& Saito, Eduardo Haruo& Higa, Claudio& Silva, Aristófanes Corrêa& Nunes, Rodolfo Acatauassú. 2019. Solid Indeterminate Nodules with a Radiological Stability Suggesting Benignity: A Texture Analysis of Computed Tomography Images Based on the Kurtosis and Skewness of the Nodule Volume Density Histogram. Pulmonary Medicine،Vol. 2019, no. 2019, pp.1-7.
https://search.emarefa.net/detail/BIM-1207074

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Borguezan, Bruno Max…[et al.]. Solid Indeterminate Nodules with a Radiological Stability Suggesting Benignity: A Texture Analysis of Computed Tomography Images Based on the Kurtosis and Skewness of the Nodule Volume Density Histogram. Pulmonary Medicine No. 2019 (2019), pp.1-7.
https://search.emarefa.net/detail/BIM-1207074

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Borguezan, Bruno Max& Lopes, Agnaldo José& Saito, Eduardo Haruo& Higa, Claudio& Silva, Aristófanes Corrêa& Nunes, Rodolfo Acatauassú. Solid Indeterminate Nodules with a Radiological Stability Suggesting Benignity: A Texture Analysis of Computed Tomography Images Based on the Kurtosis and Skewness of the Nodule Volume Density Histogram. Pulmonary Medicine. 2019. Vol. 2019, no. 2019, pp.1-7.
https://search.emarefa.net/detail/BIM-1207074

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1207074