![](/images/graphics-bg.png)
Cosine Matching Imaging Method for Rotating Scanning Synthesis Aperture Imaging Radiometer
المؤلفون المشاركون
Chen, Jianfei
Zhu, Xiaowei
Zhang, Sheng
Li, Yuanjiang
المصدر
Mathematical Problems in Engineering
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-10، 10ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-09-26
دولة النشر
مصر
عدد الصفحات
10
التخصصات الرئيسية
الملخص EN
Millimeter-wave synthesis aperture imaging radiometer (SAIR) can realize high-resolution observations without requiring the real large aperture antenna.
Among the SAIRs, the Rotating Scanning SAIR (RS-SAIR) with linear sparse array is a popular system with low redundancy and high reliability.
However, due to the lack of matched imaging methods, its imaging precision is usually low.
For improving its imaging precision, a novel Cosine Matching Imaging (CMI) method is proposed in this paper.
In CMI method, according to the characteristic of rotating projection imaging, the angle-orientation image is constituted by the 1D projection images measured by RS-SAIR in a series of angles firstly.
Then, according to the trajectory of the target in angle-orientation image, the pixel values of the brightness temperature image are extracted by cosine matching method from the angle-orientation image one by one.
The simulation results demonstrate that the proposed CMI imaging method has higher reconstruction accuracy for the RS-SAIR.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Chen, Jianfei& Zhu, Xiaowei& Zhang, Sheng& Li, Yuanjiang. 2018. Cosine Matching Imaging Method for Rotating Scanning Synthesis Aperture Imaging Radiometer. Mathematical Problems in Engineering،Vol. 2018, no. 2018, pp.1-10.
https://search.emarefa.net/detail/BIM-1208890
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Chen, Jianfei…[et al.]. Cosine Matching Imaging Method for Rotating Scanning Synthesis Aperture Imaging Radiometer. Mathematical Problems in Engineering No. 2018 (2018), pp.1-10.
https://search.emarefa.net/detail/BIM-1208890
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Chen, Jianfei& Zhu, Xiaowei& Zhang, Sheng& Li, Yuanjiang. Cosine Matching Imaging Method for Rotating Scanning Synthesis Aperture Imaging Radiometer. Mathematical Problems in Engineering. 2018. Vol. 2018, no. 2018, pp.1-10.
https://search.emarefa.net/detail/BIM-1208890
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1208890
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)