Optimal Sensor Placement and Minimum Number Selection of Sensors for Health Monitoring of Transmission Towers
المؤلفون المشاركون
Zhou, Chuandi
Liu, Yibing
Wu, Ji
Zhou, Chao
المصدر
العدد
المجلد 2020، العدد 2020 (31 ديسمبر/كانون الأول 2020)، ص ص. 1-12، 12ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2020-12-28
دولة النشر
مصر
عدد الصفحات
12
التخصصات الرئيسية
الملخص EN
Transmission towers are structurally complex, which makes it challenging to choose the right place and number of sensors for health monitoring.
In this paper, optimal sensor placement of a cat-head-type transmission tower is conducted by using the Effective Independent Method (EIM) and a method is proposed for calculating the minimum number of sensors for structural health monitoring by combining EIM and Modal Assurance Criterion (MAC).
The method for calculating the number of sensors prescribed in this paper derives a curve that shows the relationship between MAC value and the number of sensors.
It is found that the MAC value decreases with increase in the number of sensors.
When the number of sensors reaches a certain threshold, the curve tends to stabilize.
Then, the number of sensors corresponding to the minimum MAC is proposed as the minimum number of sensors.
Through calculation, the minimum number of sensors of the cat-head-type transmission tower is obtained.
Also, the optimal sensor placement results show that the position of a large number of sensors includes the position of a smaller number of sensors.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Zhou, Chuandi& Liu, Yibing& Wu, Ji& Zhou, Chao. 2020. Optimal Sensor Placement and Minimum Number Selection of Sensors for Health Monitoring of Transmission Towers. Shock and Vibration،Vol. 2020, no. 2020, pp.1-12.
https://search.emarefa.net/detail/BIM-1209714
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Zhou, Chuandi…[et al.]. Optimal Sensor Placement and Minimum Number Selection of Sensors for Health Monitoring of Transmission Towers. Shock and Vibration No. 2020 (2020), pp.1-12.
https://search.emarefa.net/detail/BIM-1209714
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Zhou, Chuandi& Liu, Yibing& Wu, Ji& Zhou, Chao. Optimal Sensor Placement and Minimum Number Selection of Sensors for Health Monitoring of Transmission Towers. Shock and Vibration. 2020. Vol. 2020, no. 2020, pp.1-12.
https://search.emarefa.net/detail/BIM-1209714
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1209714
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر