Galloping Control for Iced Conductors Using Tuned Mass Dampers with Fixed Time-Delayed Feedback
المؤلفون المشاركون
المصدر
العدد
المجلد 2019، العدد 2019 (31 ديسمبر/كانون الأول 2019)، ص ص. 1-9، 9ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2019-02-27
دولة النشر
مصر
عدد الصفحات
9
التخصصات الرئيسية
الملخص EN
A tuned mass damper with fixed time-delay feedbacks (TTMD) is first applied to suppress galloping of iced conductors.
It is different from general time-delay feedback control, which also connects an added mass to a galloping body and can absorb vibrational energy.
The two-degrees-of-freedom model captures the essential mechanical behaviors of iced conductors with TTMD undergoing galloping.
The harmonic balance method is then employed to obtain the approximate analytical solutions of the system.
Particularly, the expressions of galloping amplitude and angle frequency were obtained.
Then the influence regulations of the time-delay parameter T and strength parameter K on galloping control are fully analysed.
The results show the added fixed time-delay feedback control can promote the TTMD’s effect, when suitable time-delay parameter T and strength parameter K are chosen.
Moreover, the response amplitude and natural frequency change periodically with time-delay parameter T.
With strength parameter K increasing, the response amplitude increases or decreases for a fixed value of T and the TTMD’s effect can be enhanced.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Li, Guo& Li, Li& Zhu, Peng. 2019. Galloping Control for Iced Conductors Using Tuned Mass Dampers with Fixed Time-Delayed Feedback. Shock and Vibration،Vol. 2019, no. 2019, pp.1-9.
https://search.emarefa.net/detail/BIM-1211265
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Li, Guo…[et al.]. Galloping Control for Iced Conductors Using Tuned Mass Dampers with Fixed Time-Delayed Feedback. Shock and Vibration No. 2019 (2019), pp.1-9.
https://search.emarefa.net/detail/BIM-1211265
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Li, Guo& Li, Li& Zhu, Peng. Galloping Control for Iced Conductors Using Tuned Mass Dampers with Fixed Time-Delayed Feedback. Shock and Vibration. 2019. Vol. 2019, no. 2019, pp.1-9.
https://search.emarefa.net/detail/BIM-1211265
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1211265
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر