A New Identification Method for Bolt Looseness in Wind Turbine Towers

المؤلفون المشاركون

Xianlong, He
Tianli, She

المصدر

Shock and Vibration

العدد

المجلد 2019، العدد 2019 (31 ديسمبر/كانون الأول 2019)، ص ص. 1-10، 10ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2019-07-07

دولة النشر

مصر

عدد الصفحات

10

التخصصات الرئيسية

هندسة مدنية

الملخص EN

Flange plates are key joining components used in wind turbine towers.

Bolt looseness results in common fatigue damage in wind turbine towers.

Detailed vibration tests were carried out on six wind turbine towers with loose bolts.

First, the bolt looseness situation of each wind turbine tower was detected by the torque method.

The vibration characteristics of each tower were then tested and analyzed in detail before maintenance.

Finally, the vibration characteristics were tested and analyzed in detail after maintenance.

The experimental data analysis shows that the first-order natural frequencies of the wind turbine towers before and after bolt maintenance do not change; the damping ratio does not change significantly; and the first-order vibration mode remains effectively unchanged.

The phase difference between the upper and the lower plates of a flange has a significant and abrupt characteristic even when the bolt looseness ratio is 6%; however, the phase difference does not exhibit this characteristic after the flange bolts are retightened.

The experimental results show that compared with other vibration characteristics, the first-order phase difference characteristic of wind turbine towers is more markedly affected by the looseness of the flange bolts; hence, this characteristic can be used as a diagnostic that reflects flange bolt looseness.

Whether the flange bolts of a given tower require tightening can be identified based on whether the absolute value of the phase difference between the upper and lower plates of the flanges suddenly increases.

This research result can provide a new method for the identification of bolt looseness in wind turbine towers.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Xianlong, He& Tianli, She. 2019. A New Identification Method for Bolt Looseness in Wind Turbine Towers. Shock and Vibration،Vol. 2019, no. 2019, pp.1-10.
https://search.emarefa.net/detail/BIM-1211379

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Xianlong, He& Tianli, She. A New Identification Method for Bolt Looseness in Wind Turbine Towers. Shock and Vibration No. 2019 (2019), pp.1-10.
https://search.emarefa.net/detail/BIM-1211379

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Xianlong, He& Tianli, She. A New Identification Method for Bolt Looseness in Wind Turbine Towers. Shock and Vibration. 2019. Vol. 2019, no. 2019, pp.1-10.
https://search.emarefa.net/detail/BIM-1211379

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1211379