DCTMD Examiner Protocol: Longitudinal Evaluation on Interexaminer Reliability
المؤلفون المشاركون
Aßmus, Jörg
Rosén, Annika
Skeie, Marit Slåttelid
Frid, Paula
Mustafa, Manal
المصدر
العدد
المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-8، 8ص.
الناشر
Hindawi Publishing Corporation
تاريخ النشر
2018-09-26
دولة النشر
مصر
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
Objectives.
The objectives of this study were to assess the interexaminer agreement between one “reference” (gold standard) and each of two examiners, using the DC/TMD examination method, Axis I and to evaluate whether a recalibration changed reliability values.
Methods.
Participants (4 healthy and 12 TMD patients) in 2013 underwent a clinical examination according to DC/TMDs, Axis I.
In 2014, additionally 16 participants (4 healthy and 12 TMD patients) were recruited.
Two trainee examiners (one more experienced) and one “reference examiner” (gold standard) at both sessions assessed the participants.
Calibration preparation (2013): The clinical protocol was sent to the trainee examiners with a request that its verbal commands should be learned by heart.
An eight-hour-course was provided on the day preceding the examination session day.
Recalibration preparation (2014): The same examiners in advance to this year’s examination session were also asked to recapture the protocol’s instructions (verbal commands to be learned by heart) and go through the information from the 2013 course and encouraged to contact by e-mail in case of unclear subjects.
At a meeting prior to the examination session, they were also given the opportunities to ask questions.
The interexaminer agreements in 2013 and 2014 between the “reference” and each examiner were analysed using Bland–Altman plots, intraclass correlation coefficient, Cohen’s kappa, and consistency values.
Results.
For the majority of the gathered data, no clear change of agreement between 2013 and 2014 could be observed, and only one muscle zone in 2014 could show any clear difference in agreement between the examiners.
Conclusions.
No clear and consistent difference in the level of agreement between the two examiners could be observed, although one was more experienced than the other.
Likewise, for most components of the DC/TMD tool, recalibration of examiners did not change the reliability findings.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Skeie, Marit Slåttelid& Frid, Paula& Mustafa, Manal& Aßmus, Jörg& Rosén, Annika. 2018. DCTMD Examiner Protocol: Longitudinal Evaluation on Interexaminer Reliability. Pain Research and Management،Vol. 2018, no. 2018, pp.1-8.
https://search.emarefa.net/detail/BIM-1212604
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Skeie, Marit Slåttelid…[et al.]. DCTMD Examiner Protocol: Longitudinal Evaluation on Interexaminer Reliability. Pain Research and Management No. 2018 (2018), pp.1-8.
https://search.emarefa.net/detail/BIM-1212604
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Skeie, Marit Slåttelid& Frid, Paula& Mustafa, Manal& Aßmus, Jörg& Rosén, Annika. DCTMD Examiner Protocol: Longitudinal Evaluation on Interexaminer Reliability. Pain Research and Management. 2018. Vol. 2018, no. 2018, pp.1-8.
https://search.emarefa.net/detail/BIM-1212604
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references
رقم السجل
BIM-1212604
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر