Evaluation of Threshold Values for Root Canal Filling Voids in Micro-CT and Nano-CT Images

المؤلفون المشاركون

Celikten, Berkan
Orhan, Kaan
Huang, Yan
Jacobs, Reinhilde
de Faria Vasconcelos, Karla
Nicolielo, Laura Ferreira Pinheiro
Buyuksungur, Arda
Van Dessel, Jeroen

المصدر

Scanning

العدد

المجلد 2018، العدد 2018 (31 ديسمبر/كانون الأول 2018)، ص ص. 1-6، 6ص.

الناشر

Hindawi Publishing Corporation

تاريخ النشر

2018-07-16

دولة النشر

مصر

عدد الصفحات

6

التخصصات الرئيسية

تكنولوجيا المعلومات وعلم الحاسوب

الملخص EN

While several materials and techniques have been used to assess the quality of root canal fillings in micro-CT images, the lack of standardization in scanning protocols has produced conflicting results.

Hence, the aim of this study was to determine a cutoff voxel size value for the assessment of root canal filling voids in micro-CT and nano-CT images.

Twenty freshly extracted mandibular central incisors were used.

Root canals were prepared with nickel titanium files to an ISO size 40/0.06 taper and then filled with a single cone (40/0.06 taper) and AH Plus sealer.

The teeth were scanned with different voxel sizes with either micro-CT (5.2, 8.1, 11.2, and 16.73 μm) or nano-CT (1.5 and 5.0 μm) equipment.

Images were reconstructed and analyzed with the NRecon and CTAn software.

Void proportion and void volume were calculated for each tooth in the apical, middle, and coronal thirds of the root canal.

Kruskal-Wallis and post hoc Mann–Whitney U tests were performed with a significance level of 5%.

In micro-CT images, significantly different results were detected among the tested voxel sizes for void proportion and void volume, whereas no such differences were found in nano-CT images (p>0.05).

Micro-CT images showed higher void numbers over the entire root length, with statistically significant differences between the voxel size of 16.73 μm and the other sizes (p<0.05).

The values of the different nano-CT voxel sizes did not significantly differ from those of the micro-CT (5.2, 8.1, and 11.2 μm), except for the voxel size of 16.73 μm (p<0.05).

All tested voxel sizes enabled the detection of root canal filling voids except for the voxel size of 16.73 μm.

Bearing in mind the limitations of this study, it seems that a voxel size of 11.2 μm can be used as a reliable cutoff value for the assessment of root canal filling voids in micro-CT imaging.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Orhan, Kaan& Jacobs, Reinhilde& Celikten, Berkan& Huang, Yan& de Faria Vasconcelos, Karla& Nicolielo, Laura Ferreira Pinheiro…[et al.]. 2018. Evaluation of Threshold Values for Root Canal Filling Voids in Micro-CT and Nano-CT Images. Scanning،Vol. 2018, no. 2018, pp.1-6.
https://search.emarefa.net/detail/BIM-1213020

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Orhan, Kaan…[et al.]. Evaluation of Threshold Values for Root Canal Filling Voids in Micro-CT and Nano-CT Images. Scanning No. 2018 (2018), pp.1-6.
https://search.emarefa.net/detail/BIM-1213020

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Orhan, Kaan& Jacobs, Reinhilde& Celikten, Berkan& Huang, Yan& de Faria Vasconcelos, Karla& Nicolielo, Laura Ferreira Pinheiro…[et al.]. Evaluation of Threshold Values for Root Canal Filling Voids in Micro-CT and Nano-CT Images. Scanning. 2018. Vol. 2018, no. 2018, pp.1-6.
https://search.emarefa.net/detail/BIM-1213020

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references

رقم السجل

BIM-1213020