In-plane shear strengthening of masonry walls after damage
العناوين الأخرى
تقوية مقاومة القص الجانبية للجدران بعد التضرر
المؤلفون المشاركون
Said, Jalal Ahmad
Rauf, Ahmad Muhammad
المصدر
Sulaimani Journal of Engineering Sciences
العدد
المجلد 7، العدد 1 (30 إبريل/نيسان 2020)، ص ص. 65-85، 21ص.
الناشر
تاريخ النشر
2020-04-30
دولة النشر
العراق
عدد الصفحات
21
التخصصات الرئيسية
الموضوعات
الملخص EN
This study investigates the effect of 5 different strengthening materials on damaged Un-Reinforced Masonry (URM) brick walls under an in-plane lateral loading and a predefined uniform vertical load.
Five clay brick walls with a dimension of (1200 * 935 * 115) mm were tested then strengthened with plastic mesh, glass fiber mesh, steel mesh, wild cane strips, and chopped steel fibers.
The walls were tested again up to failure in order to determine the best material in terms of shear strength and ductility.
Two more walls were tested similarly without strengthening to serve as control walls.
Based on the experimental results, GM-r (strengthened with glass fiber mesh) had the highest ductility factor of 23.2 and showed the best strength retention amongst the strengthened walls.
OG-r (strengthened with wild cane grid) had the highest toughness ratio value of 10.1 even though it is not suitable for exterior walls due to biological factors such as rotting and incompatibility with high moisture areas.
SM-r (strengthened with steel mesh) retained 89% of the damaged wall and at the same time inadequate in seismic areas due to its sudden brittle de-bonding failure.
Walls PM-r and SF-r lacked strength and ductility retention, respectively, to be considered as a feasible option in sustaining lateral loads.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Rauf, Ahmad Muhammad& Said, Jalal Ahmad. 2020. In-plane shear strengthening of masonry walls after damage. Sulaimani Journal of Engineering Sciences،Vol. 7, no. 1, pp.65-85.
https://search.emarefa.net/detail/BIM-1262520
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Rauf, Ahmad Muhammad& Said, Jalal Ahmad. In-plane shear strengthening of masonry walls after damage. Sulaimani Journal of Engineering Sciences Vol. 7, no. 1 (Apr. 2020), pp.65-85.
https://search.emarefa.net/detail/BIM-1262520
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Rauf, Ahmad Muhammad& Said, Jalal Ahmad. In-plane shear strengthening of masonry walls after damage. Sulaimani Journal of Engineering Sciences. 2020. Vol. 7, no. 1, pp.65-85.
https://search.emarefa.net/detail/BIM-1262520
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
-
رقم السجل
BIM-1262520
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر