Study of ethanol analysis in blood by headspace gas chromatography flame ionization detector for ensuring validation
المؤلفون المشاركون
Hamzah, Ahmad Mubarak Ahmad
Said, Ahmad al-Sadiq Muhammad
المصدر
SUST Journal of Total Quality Management
العدد
المجلد 21، العدد 1 (30 يونيو/حزيران 2020)، ص ص. 85-92، 8ص.
الناشر
جامعة السودان للعلوم و التكنولوجيا عمادة البحث العلمي
تاريخ النشر
2020-06-30
دولة النشر
السودان
عدد الصفحات
8
التخصصات الرئيسية
الملخص EN
-Ensuring the validity of laboratory results is one of the general requirements for the competence to carry out tests.
The results provided by the laboratory should be satisfied as far as possible/where relevant with the quality of the measurements, statement of conformity with standard requirements or specifications.
A laboratory performing testing should have a procedure for monitoring the validity of its results.
To ensure the validity of laboratory results as required or deemed appropriate for monitoring laboratory performance, a procedure for monitoring the validity of results was established.
The activities that are required to fulfil validity of results based on analytical method performance characteristics were identified, analyzed, evaluated, monitored and reviewed.
To assure the validity of the results, statistical techniques were applied to the monitoring and reviewing of the performance characteristics resulting data.
Specificity, selectivity, linearity, acceptance limits, intermediate checks on measuring equipment, precision and accuracy, of the developed method (Ethanol analysis in blood by Headspace/GC/FID) were monitored using reference materials and positive blood control sample.
The present study, assist the analyst to maintain a high level of test performance, reduces variation in test results, improves the confidence of testing results, able to translate the data into answers, which directly relate to solving the customer’s problem.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Hamzah, Ahmad Mubarak Ahmad& Said, Ahmad al-Sadiq Muhammad. 2020. Study of ethanol analysis in blood by headspace gas chromatography flame ionization detector for ensuring validation. SUST Journal of Total Quality Management،Vol. 21, no. 1, pp.85-92.
https://search.emarefa.net/detail/BIM-1275378
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Hamzah, Ahmad Mubarak Ahmad& Said, Ahmad al-Sadiq Muhammad. Study of ethanol analysis in blood by headspace gas chromatography flame ionization detector for ensuring validation. SUST Journal of Total Quality Management Vol. 21, no. 1 (2020), pp.85-92.
https://search.emarefa.net/detail/BIM-1275378
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Hamzah, Ahmad Mubarak Ahmad& Said, Ahmad al-Sadiq Muhammad. Study of ethanol analysis in blood by headspace gas chromatography flame ionization detector for ensuring validation. SUST Journal of Total Quality Management. 2020. Vol. 21, no. 1, pp.85-92.
https://search.emarefa.net/detail/BIM-1275378
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references : p. 91-92
رقم السجل
BIM-1275378
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
![](/images/ebook-kashef.png)
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر
![](/images/kashef-image.png)