The accuracy of fine needle aspiration cytology for the diagnosis of non-thyroid neck masses

المؤلفون المشاركون

al-Shari, Ahmad A.
Ashukaybi, Umar Y.
al-Batayinah, Muhammad M.
al-Jarrah, Muhammad H.
al-Alawinah, Ahmad M.
al-Hammuri, Iman H.
al-Suud, Asma A.

المصدر

Journal of the Royal Medical Services

العدد

المجلد 28، العدد 3 (31 ديسمبر/كانون الأول 2021)، ص ص. 69-78، 10ص.

الناشر

الخدمات الطبية الملكية الأردنية

تاريخ النشر

2021-12-31

دولة النشر

الأردن

عدد الصفحات

10

التخصصات الرئيسية

الطب البشري

الملخص EN

Objectives: The aim of the study was to evaluate the accuracy of fine needle aspiration cytology (FNAC) in the diagnosis of neck masses.

Materials and methods: A retrospective study was undertaken of 188 neck masses that had undergone FNAC, over a five-year period from 2010-2015, at Prince Rashid Bin Al-Hasan Hospital.

The FNAC reports were reviewed and compared to the final diagnosis.

The final diagnosis was determined either by the final histopathological diagnosis or the clinical outcome.

Results: 110 FNACs were included in the study.

The sensitivity, specificity and accuracy of FNAC in distinguishing neoplastic from non-neoplastic cervical masses (including salivary gland masses) were 90%, 86% and 94%, respectively.

The sensitivity of FNAC in distinguishing malignant from benign neck masses (including salivary gland masses) was 46% with a specificity of 98% and an overall accuracy of 85%.

In distinguishing malignant from benign salivary gland masses, the sensitivity of FNAC was 8% with a specificity of 98% and accuracy of 78%.

Regarding lymphoma, FNAC had sensitivity of 71% and specificity of 98% with a diagnostic accuracy of 96%.

The sensitivity of FNAC in detecting metastatic carcinoma to the neck was 83%, with a specificity of 100% Conclusion: Although FNAC seems to be an attractive investigation, it should be used cautiously in assessing salivary gland diseases, cystic lumps of the neck and lymphomas.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

al-Shari, Ahmad A.& al-Batayinah, Muhammad M.& al-Jarrah, Muhammad H.& al-Alawinah, Ahmad M.& al-Hammuri, Iman H.& Ashukaybi, Umar Y.…[et al.]. 2021. The accuracy of fine needle aspiration cytology for the diagnosis of non-thyroid neck masses. Journal of the Royal Medical Services،Vol. 28, no. 3, pp.69-78.
https://search.emarefa.net/detail/BIM-1326115

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

al-Shari, Ahmad A.…[et al.]. The accuracy of fine needle aspiration cytology for the diagnosis of non-thyroid neck masses. Journal of the Royal Medical Services Vol. 28, no. 3 (Dec. 2021), pp.69-78.
https://search.emarefa.net/detail/BIM-1326115

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

al-Shari, Ahmad A.& al-Batayinah, Muhammad M.& al-Jarrah, Muhammad H.& al-Alawinah, Ahmad M.& al-Hammuri, Iman H.& Ashukaybi, Umar Y.…[et al.]. The accuracy of fine needle aspiration cytology for the diagnosis of non-thyroid neck masses. Journal of the Royal Medical Services. 2021. Vol. 28, no. 3, pp.69-78.
https://search.emarefa.net/detail/BIM-1326115

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references : p. 76-78

رقم السجل

BIM-1326115