Optimization of heat source temperature for single and double effect vapor absorption refrigeration system
المؤلفون المشاركون
Shaban, S.
al-Jundi, E.
Jalal, M.
المصدر
العدد
المجلد 2019، العدد 162 (30 يونيو/حزيران 2019)، ص ص. 17-33، 17ص.
الناشر
جامعة حلوان كلية الهندسة بالمطرية
تاريخ النشر
2019-06-30
دولة النشر
مصر
عدد الصفحات
17
التخصصات الرئيسية
الموضوعات
الملخص EN
Studying the orption refrigeration systems is very important in recent years because the primary energy that is used in an orption system can be either heat available from a residual source or even a renewable one.
Therefore, these systems not only use the energy that would be rejected to the environment, but they also avoid the consumption of fossil fuel or electrical energies.
In this study, the energy and exergy analysis of both single & double effect water-LiBr orption system is presented.
The work is carried out for air conditioning applications.
The investigated performance parameters are the coefficient of performance and the exergy efficiency.
The effect of the operating temperatures on such parameters is included.
An analysis of the individual components is also presented.
The most noticeable effect is observed for the case of the exergy efficiency for the orber and the generator.
The obtained results allow the identification of the parameters that may influence the exergy efficiency of the adiabatic orption system.
A thermodynamic optimization analysis of both single & double effect LiBr-H2O orption cooling system of fixed cooling capacity is conducted based on the first and the second laws of thermodynamics.
Mathematical models that derived from the thermodynamics theory are employed in the engineering equation solver (EES) software to perform the calculations.
It is observed that the optimum heat source temperature decreases with the evaporator temperature and increases with the condenser temperature.
Hence it is feasible to find out an optimum heat source temperature for various condenser-evaporator temperatures.
Evaluation of the optimized system is conducted owing to the fact that the optimum heat source temperature corresponding to the maximum COP and the minimum exergy destruction is not identical.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Jalal, M.& Shaban, S.& al-Jundi, E.. 2019. Optimization of heat source temperature for single and double effect vapor absorption refrigeration system. Engineering Research Journal،Vol. 2019, no. 162, pp.17-33.
https://search.emarefa.net/detail/BIM-1364622
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Jalal, M.…[et al.]. Optimization of heat source temperature for single and double effect vapor absorption refrigeration system. Engineering Research Journal No. 162 (2019), pp.17-33.
https://search.emarefa.net/detail/BIM-1364622
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Jalal, M.& Shaban, S.& al-Jundi, E.. Optimization of heat source temperature for single and double effect vapor absorption refrigeration system. Engineering Research Journal. 2019. Vol. 2019, no. 162, pp.17-33.
https://search.emarefa.net/detail/BIM-1364622
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
-
رقم السجل
BIM-1364622
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر