Evaluation of different polymerisation methods of ocular prosthesis acrylic resins on subcutaneous tissue inflammatory response in rats

المؤلفون المشاركون

Bitencourt, Sandro B.
Takamyia, Aline S.
Penitente, Paulo A.
Silva, Emily VF. da
Santos, Daniela M. dos
Brito, Victor GB.
Oliveira, Sandra HP. de
Goiato, Marcelo C.

المصدر

Sultan Qaboos University Medical Journal

العدد

المجلد 22، العدد 2 (31 مايو/أيار 2022)، ص ص. 233-240، 8ص.

الناشر

جامعة السلطان قابوس كلية الطب و العلوم الصحية

تاريخ النشر

2022-05-31

دولة النشر

سلطنة عمان

عدد الصفحات

8

التخصصات الرئيسية

الطب البشري

الملخص EN

Objectives : This study aimed to evaluate the influence of different polymerisation methods of acrylic resin for ocular prostheses on the subcutaneous tissue inflammatory response of rats.

Methods : The study was conducted at the Basic Sciences Department, Araçatuba Dental School, São Paulo State University (UNESP), Brazil, from 2016 to 2018.

The samples were prepared by water bath (WB), microwave energy (MW) or autopolymerisation (AP) (n = 20 samples per group).

The inflammatory response (cell count and immunohistochemical analysis of interleukin [IL]-1B, IL-6, tumour necrosis factor [TNF]-a, IL-17 and macrophage inflammatory protein-3a) was analysed by the implantation of a sample from each group in the subcutaneous tissue of 20 Wistar rats and evaluated after seven, 15, 30 and 60 days.

The quantitative and qualitative data were analysed using analysis of variance and Tukey tests (P <0.05) and visual comparison, respectively.

Results : There was a moderate inflammatory infiltrate for the MW and AP groups and a light infiltrate for the WB group after seven days.

The inflammatory infiltrate and the immunolabeling of tested targets decreased gradually during the 60-day period.

The AP group had the highest immunolabeling of TNF-α (seven days), IL-1ẞ and IL-17 (at 15 and 30 days) and IL-6 (at 30 and 60 days).

The WB and MW groups showed greater immunolabeling at 15 and 30 days, while the MW group also had high results at 60 days.

Conclusion : Polymerisation by microwave energy and by chemical activation resulted in a higher inflammatory response.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Takamyia, Aline S.& Goiato, Marcelo C.& Bitencourt, Sandro B.& Penitente, Paulo A.& Silva, Emily VF. da& Santos, Daniela M. dos…[et al.]. 2022. Evaluation of different polymerisation methods of ocular prosthesis acrylic resins on subcutaneous tissue inflammatory response in rats. Sultan Qaboos University Medical Journal،Vol. 22, no. 2, pp.233-240.
https://search.emarefa.net/detail/BIM-1494219

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Takamyia, Aline S.…[et al.]. Evaluation of different polymerisation methods of ocular prosthesis acrylic resins on subcutaneous tissue inflammatory response in rats. Sultan Qaboos University Medical Journal Vol. 22, no. 2 (May. 2022), pp.233-240.
https://search.emarefa.net/detail/BIM-1494219

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Takamyia, Aline S.& Goiato, Marcelo C.& Bitencourt, Sandro B.& Penitente, Paulo A.& Silva, Emily VF. da& Santos, Daniela M. dos…[et al.]. Evaluation of different polymerisation methods of ocular prosthesis acrylic resins on subcutaneous tissue inflammatory response in rats. Sultan Qaboos University Medical Journal. 2022. Vol. 22, no. 2, pp.233-240.
https://search.emarefa.net/detail/BIM-1494219

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references : p. 239-245

رقم السجل

BIM-1494219