الملخص EN
Background: Amblyopia is a relatively common condition in which visual acuity through an eye is subnormal despite no overt pathology.
Pattern visual evoked potential (PVEP) can detect any defect from optic nerve to occipital cortex and pattern electroretinogram (PERG) can detect retinal defects specially the ganglion layers. This study was performed to evaluate the cortical and retinal activity in strabismic and anisometropic amblyopia. Methods: PVEP and PERG were recorded simultaneously in 40 amblyopes (20 strabismics and 20 anisometropics) and 20 normal control subjects.
Normal subjects were age and sex matched with patients. Results: The P100 latency in PVEP was increased in both groups of patients but the P100 amplitude was reduced only in anisometropic group.
In PERG, the amplitude of P50 was reduced in all patients with no significant change in latency. Conclusion: Beside reduced PVEP responses in strabismic and anisometropic amblyopia, the activity of retina reduced too.
It is likely that retinal impulses can affect the development of visual system.
نمط استشهاد جمعية علماء النفس الأمريكية (APA)
Heravian, J.& Daneshvar, R.& Dashti, F& Azimi, A.& Ostadi-Moghaddam, H.& Yekta, A. A.…[et al.]. 2011. Simultaneous pattern visual evoked potential and pattern electroretinogram in strabismic and anisometropic amblyopia. Iranian Red Crescent Medical Journal،Vol. 13, no. 1, pp.21-26.
https://search.emarefa.net/detail/BIM-252041
نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)
Heravian, J.…[et al.]. Simultaneous pattern visual evoked potential and pattern electroretinogram in strabismic and anisometropic amblyopia. Iranian Red Crescent Medical Journal Vol. 13, no. 1 (Jan. 2011), pp.21-26.
https://search.emarefa.net/detail/BIM-252041
نمط استشهاد الجمعية الطبية الأمريكية (AMA)
Heravian, J.& Daneshvar, R.& Dashti, F& Azimi, A.& Ostadi-Moghaddam, H.& Yekta, A. A.…[et al.]. Simultaneous pattern visual evoked potential and pattern electroretinogram in strabismic and anisometropic amblyopia. Iranian Red Crescent Medical Journal. 2011. Vol. 13, no. 1, pp.21-26.
https://search.emarefa.net/detail/BIM-252041
نوع البيانات
مقالات
لغة النص
الإنجليزية
الملاحظات
Includes bibliographical references : p. 25-26.
رقم السجل
BIM-252041
قاعدة معامل التأثير والاستشهادات المرجعية العربي "ارسيف Arcif"
أضخم قاعدة بيانات عربية للاستشهادات المرجعية للمجلات العلمية المحكمة الصادرة في العالم العربي
تقوم هذه الخدمة بالتحقق من التشابه أو الانتحال في الأبحاث والمقالات العلمية والأطروحات الجامعية والكتب والأبحاث باللغة العربية، وتحديد درجة التشابه أو أصالة الأعمال البحثية وحماية ملكيتها الفكرية. تعرف اكثر