Corrosion of boiler tubes in south Baghdad electric station

المؤلفون المشاركون

Huwayl, Cecilia Khushaba
Lazar, Janet

المصدر

Iraqi Journal of Chemical and Petroleum Engineering

العدد

المجلد 11، العدد 3 (30 سبتمبر/أيلول 2010)، ص ص. 1-7، 7ص.

الناشر

جامعة بغداد كلية الهندسة

تاريخ النشر

2010-09-30

دولة النشر

العراق

عدد الصفحات

7

التخصصات الرئيسية

الهندسة الميكانيكية

الموضوعات

الملخص EN

The corrosion of low carbon steel boiler tubes in demi water had been investigated.

The purpose of this investigation was to determine the change produced in corrosion behavior of the carbon steel as a result of the specific presence of chloride and copper ions in the water under different temperatures.

For low carbon steel experiments, the temperature was taken in three levels (125, 175, and 215°C) under about 27 bar pressure and 1500 rpm in autoclave.

Using weight loss technique, the corrosion rate ranges from (85 to 789 gmd) for low carbon steel boiler tubes.

نمط استشهاد جمعية علماء النفس الأمريكية (APA)

Huwayl, Cecilia Khushaba& Lazar, Janet. 2010. Corrosion of boiler tubes in south Baghdad electric station. Iraqi Journal of Chemical and Petroleum Engineering،Vol. 11, no. 3, pp.1-7.
https://search.emarefa.net/detail/BIM-287170

نمط استشهاد الجمعية الأمريكية للغات الحديثة (MLA)

Huwayl, Cecilia Khushaba& Lazar, Janet. Corrosion of boiler tubes in south Baghdad electric station. Iraqi Journal of Chemical and Petroleum Engineering Vol. 11, no. 3 (Sep. 2010), pp.1-7.
https://search.emarefa.net/detail/BIM-287170

نمط استشهاد الجمعية الطبية الأمريكية (AMA)

Huwayl, Cecilia Khushaba& Lazar, Janet. Corrosion of boiler tubes in south Baghdad electric station. Iraqi Journal of Chemical and Petroleum Engineering. 2010. Vol. 11, no. 3, pp.1-7.
https://search.emarefa.net/detail/BIM-287170

نوع البيانات

مقالات

لغة النص

الإنجليزية

الملاحظات

Includes bibliographical references : p. 7

رقم السجل

BIM-287170